MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.tp.0000120535.89925.ca

Медицинская библиотека · Transplantation · 2004

Pancreas preservation with University of Wisconsin and Celsior solutions: a single-center, prospective, randomized pilot study.

Boggi Ugo, Vistoli Fabio, Del Chiaro Marco, Signori Stefano, Croce Chiara, Pietrabissa Andrea, Berchiolli Raffaella, Marchetti Piero, Del Prato Stefano, Mosca Franco

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Celsior is an extracellular-type, low-viscosity, preservation solution already used for heart, lung, liver, and kidney transplantation. We report the results of a single-center, prospective, randomized pilot study specifically designed to compare the safety profile of Celsior solution with University of Wisconsin (UW) solution in clinical pancreas transplantation.

METHODS

A total of 105 consecutive procurements were randomized to graft preservation with UW (n=53) solution or Celsior (n=52) solution. The groups were comparable with regard to all donor and recipient characteristics.

RESULTS

Five grafts were discarded and 100 grafts (50 UW vs. 50 Celsior) were transplanted. Mean cold and warm ischemia times were 11.0 +/- 2.1 hr and 37.2 +/- 6.0 min for UW compared with 10.8 +/- 1.8 hr and 38.1 +/- 5.9 min for Celsior (P =not significant). Delayed endocrine pancreas function was recorded in one graft preserved with UW solution. Eleven recipients (UW 12% vs. Celsior 10%, P =not significant) required a relaparotomy. The mean serum levels of glucose, amylase, and lipase remained comparable between the study arms at equivalent intervals after transplantation. One recipient died with functioning grafts in each study arm; two further grafts were lost to arterial thrombosis (Celsior) and chronic rejection (UW), respectively. Actuarial 1-year patient and graft survival rates overlapped in the two study arms (98% and 96%, respectively).

CONCLUSIONS

Within the range of cold ischemia time reported in this study, UW and Celsior solutions have similar safety profiles for pancreas preservation.

Для цитирования: Boggi Ugo, Vistoli Fabio, Del Chiaro Marco, Signori Stefano, Croce Chiara, Pietrabissa Andrea, Berchiolli Raffaella, Marchetti Piero, Del Prato Stefano, Mosca Franco. Pancreas preservation with University of Wisconsin and Celsior solutions: a single-center, prospective, randomized pilot study.. Transplantation. 2004. DOI: 10.1097/01.tp.0000120535.89925.ca.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.