MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.13102

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2016

Sex Differences in Inappropriate ICD Device Therapies: MADIT-II and MADIT-CRT.

Tompkins Christine M, McNitt Scott, Polonsky Bronislava, Daubert James P, Wang Paul J, Moss Arthur J, Zareba Wojciech, Kutyifa Valentina

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

Approximately 10-20% of ICD recipients receive inappropriate device therapies. The purpose of this study was to compare the frequency of inappropriate therapies (IT) between men and women enrolled in MADIT II and MADIT-CRT, and assess for potential adverse outcomes.

METHODS

The electrograms for each ICD or CRT-D therapy, defined as either ATP or shock, were reviewed by adjudication committees for both studies. ICD therapy was considered inappropriate if it was delivered for reasons other than VT/VF. The rhythm triggering IT was categorized as atrial fibrillation/flutter, SVT, or inappropriate sensing when possible.

RESULTS

One thousand nine hundred and fifty-four men and 556 women received ICD or CRT-D devices. The risk of IT was significantly lower in women than men (9.2% vs. 13.5%, P = 0.006). The most common cause of IT in men was atrial fibrillation (38%) and SVT in women (43%). Inappropriate shock was not associated with increased mortality in either women (HR 0.82 [95% CI 0.11-6.08]; P = NS) or men (HR 1.37 [95% CI 0.75-2.48]; P = NS) by multivariate analysis. Conversely, appropriate shock therapy strongly correlated with increased risk of death during subsequent post-shock follow-up in women (HR 5.99 [95% CI 2.75-13.02]; P < 0.0001) and men (HR 2.61 [95% CI 1.82-3.74]; P < 0.0001).

CONCLUSIONS

Women experience significantly less IT than men, partially explained by the increased frequency of atrial fibrillation in men. IT was not associated with increased mortality in either sex. Appropriate shock therapy was a strong predictor of death in both, with women showing a 2-fold higher risk than men during post-shock long-term follow-up.

Для цитирования: Tompkins Christine M, McNitt Scott, Polonsky Bronislava, Daubert James P, Wang Paul J, Moss Arthur J, Zareba Wojciech, Kutyifa Valentina. Sex Differences in Inappropriate ICD Device Therapies: MADIT-II and MADIT-CRT.. Journal of cardiovascular electrophysiology. 2016. DOI: 10.1111/jce.13102.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.