MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/ani12172296

Медицинская библиотека · Animals : an open access journal from MDPI · 2022

Reference Values and Repeatability of Pulsed Wave Doppler Echocardiography Parameters in Normal Donkeys.

Marzok Mohamed, Almubarak Adel I, Al Mohamad Zakriya, Salem Mohamed, Farag Alshimaa M, Ibrahim Hussam M, El-Ashker Maged R, El-Khodery Sabry

СтатьяПеревод пока не подготовлен

Аннотация

In the present study, thirty clinically healthy donkeys were used to establish the reference values and repeatability for Pulsed Wave Doppler echocardiographic variables of the mitral valve, aortic valve and myocardial performance. 2-dimensional Color flow mapping and spectral Doppler modes were performed. For the mitral valve, the mean velocity, pressure gradient and duration of E-wave were 57.7 ± 12.5 cm/s, 1.4 ± 0.7 mmHg and 0.4 ± 0.13 s, respectively. The velocity, pressure gradient and duration of the A-wave were 32.3 ± 9.1 cm/s, 0.3 ± 0.04 mmHg and 0.3 ± 0.1 s, respectively. The mitral valve area, pressure half time, pulsatility index (PI), resistance index (RI) and velocity time integral (VTI) were 1.8 ± 0.5 cm2, 66 ± 17 ms, 2.8 ± 1.4, 0.9 ± 0.03 and 19.1 ± 5.7 cm, respectively. For the aortic valve, the mean velocity was 64.9 ± 10.4 cm/s, pressure gradient was 1.8 ± 0.4 mmHg, pulsatility index was 1.4 ± 0.3, resistance index was 0.9 ± 0.02, VTI was 25.02 ± 6.2 cm, systolic/diastolic was 19 ± 4.7 and heart rate was 95.7 ± 28.9 per minute. For Myocardial Performance Index (LV)-Tei Index, the mean ejection, isovolumic relaxation, isovolumic contraction time and myocardial performance index were 0.24 ± 0.01, 0.14 ± 0.01, 0.14 ± 0.02 and 1.2 ± 0.1 s, respectively. The results of the present study provide the reference values of PW echocardiographic parameter measurements in normal adult donkeys. Such reference values are helpful, especially when confronted with clinical cases with cardiovascular disorders.

Для цитирования: Marzok Mohamed, Almubarak Adel I, Al Mohamad Zakriya, Salem Mohamed, Farag Alshimaa M, Ibrahim Hussam M, El-Ashker Maged R, El-Khodery Sabry. Reference Values and Repeatability of Pulsed Wave Doppler Echocardiography Parameters in Normal Donkeys.. Animals : an open access journal from MDPI. 2022. DOI: 10.3390/ani12172296.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.