MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02676591251412308

Медицинская библиотека · Perfusion · 2025

Comparison of the Quantra® QPlus sonorheometry with conventional hemostasis laboratory and TEG-5000® parameters.

Frédéric Stephan, Istaces Nicolas, Lovqvist Linda, Aunac Sophie

СтатьяОбзорПеревод пока не подготовлен

Аннотация

ObjectiveTo compare and evaluate, a new viscoelastic point-of-care device, the Quantra QPlus® parameters with conventional hemostasis tests and TEG-5000® parameters.Design, Material and MethodsThis prospective homocentric observational study took place between January and June 2024 at the main community site Hospital, Jolimont's Hospital on adult patients undergoing elective cardiac surgery using cardiopulmonary bypass (CPB). Paired perioperative citrated and EDTA blood samples were collected and sent directly to the laboratory for analysis. The blood was analyzed in one hand with TEG-5000® (K, MA and alpha angle) in cardiac operating room and afterwards, simultaneously with Quantra QPlus® (CTH, FCS, PCS), citrate platelet count with specific fluorescent agent (PLT-F) and standard haemostasis testing (PT/INR, aPTT, Clauss Fibrinogen).ResultsMethod comparison analysis shows that Quantra's Parameters PCS and FCS were well correlated with PLT-F and Fibrinogen while TEG-5000® parameter were less. FCS and Alpha Angle predicted a Clauss Fibrinogen <150 mg/dL with an area under the curve (AUC) respectively of 0.899 (n = 66) and 0.815 (n = 54). PCS and MA predicted a Platelet count <150k/µL with an AUC of 0.793 (n = 62) and 0.807 (n = 54) respectively. CTH and K predicted an aPTT (actin FS on CS-5100) >29,0s with an AUC of 0.864 (n = 60) and 0.702 (n = 60) respectively.ConclusionStrong correlations were observed between quantra parameters FCS and PCS with Clauss Fibrinogen and Platelet count. While Performance from ROC curves for predicted thrombocytopenia <150k platelet/µL is similar with TEG-5000, they are better for predicted fibrinogen concentration and prolonged aPTT.

Для цитирования: Frédéric Stephan, Istaces Nicolas, Lovqvist Linda, Aunac Sophie. Comparison of the Quantra® QPlus sonorheometry with conventional hemostasis laboratory and TEG-5000® parameters.. Perfusion. 2025. DOI: 10.1177/02676591251412308.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.