Аннотация

BACKGROUND

Hirsutism and hypertrichosis are common problems. Laser-assisted hair removal has recently become a popular method to remove unwanted hair. However, histologic changes of the hair follicle after exposure to laser continue to require further investigation.

OBJECTIVE

To determine the thermal effect of a millisecond Nd:YAG hair removal laser.

METHODS

Six patients with black hair were treated with 50 msec pulsed Nd:YAG laser at fluences 30, 50 or 100 J/cm(2). Histologic examinations were performed on each laser-treated site at 24-72 hours after laser exposure.

RESULTS

Fluence-dependent selective thermal injury to follicles was seen. The average depth of acute laser injury at fluences 30, 50 and 100 J/cm(2) were 1.06, 0.85 and 1.11 millimeters, respectively.

CONCLUSIONS

Long-pulsed millisecond Nd:YAG lasers produce selective thermal damage of hair follicles. Varied laser fluences used in this study did not statistically alter the degree of thermal injury.

Для цитирования: Goldberg D J, Silapunt S. Histologic evaluation of a millisecond Nd:YAG laser for hair removal.. Lasers in surgery and medicine. 2001. DOI: 10.1002/lsm.1033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.