MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4293/jsls.2017.00060

Медицинская библиотека · JSLS : Journal of the Society of Laparoendoscopic Surgeons · 2018

Urinary Bladder Matrix Reinforcement for Laparoscopic Hiatal Hernia Repair.

Zografakis John, Johnston Gregory, Haas Jennifer, Berbiglia Lindsay, Bedford Tyler, Spear Justin, Dan Adrian, Pozsgay Mark

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Synthetic mesh reinforcement during laparoscopic hiatal hernia repair (LHHR) reduces recurrence. Biologically derived mesh is also associated with reduced recurrence. Urinary bladder matrix (UBM), a biologically derived extracellular matrix mesh, has shown clinical success. We wanted to determine the safety and efficacy of LHHR with porcine UBM reinforcement.

METHODS

This retrospective, single-surgeon study reviewed clinical data on patients who underwent LHHR from August 2009 through May 2014, with diaphragmatic reinforcement with porcine UBM mesh. Primary outcomes were (1) recurrence-a >2-cm defect above the diaphragm at 3 months; (2) intra- and postoperative complications; (3) pre- and postoperative esophageal reflux (GERD) or dysphagia; and (4) cessation of proton pump inhibitor (PPI).

RESULTS

Sixty-two patients who had LHHR with UBM mesh were studied (mean age, 62 years, 53 women, mean body mass index 32.7 kg/m2) Before surgery 98% had GERD, 19% had dysphagia, and 98% were on PPI. Postoperative UGIS was performed on 66% 3 months after surgery, and 19% had a recurrence of >2 cm; 56% remained on PPI, and 16% (P < .001) remained symptomatic. Dysphagia improved in 75% (P = .05). No intraoperative complications were recorded. One postoperative mortality occurred secondary to an unrelated cardiac event.

CONCLUSIONS

UBM mesh was effective and safe for LHHR. In addition to reducing the rate of recurrence compared to unreinforced primary repair, the properties of UBM, including site-specific constructive tissue remodeling, may add benefits over other biologic products. This study represents an evaluation of UBM mesh in a large cohort of patients who underwent LHHR.

Для цитирования: Zografakis John, Johnston Gregory, Haas Jennifer, Berbiglia Lindsay, Bedford Tyler, Spear Justin, Dan Adrian, Pozsgay Mark. Urinary Bladder Matrix Reinforcement for Laparoscopic Hiatal Hernia Repair.. JSLS : Journal of the Society of Laparoendoscopic Surgeons. 2018. DOI: 10.4293/jsls.2017.00060.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.