MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjophth-2023-001493

Медицинская библиотека · BMJ open ophthalmology · 2023

Quality assessment of non-mydriatic fundus photographs for glaucoma screening in primary healthcare centres: a real-world study.

Chen Qi, Zhou Mengtian, Cao Yang, Zheng Xuanli, Mao Huiyan, Lei Changrong, Lin Wanglong, Jiang Junhong, Chen Yize, Song Di, Xu Xiang, Ye Cong, Liang Yuanbo

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

This study assessed the quality distribution of non-mydriatic fundus photographs (NMFPs) in real-world glaucoma screening and analysed its influencing factors.

METHODS

This cross-sectional study was conducted in primary healthcare centres in the Yinzhou District, China, from 17 March to 3 December 2021. The quality distribution of bilateral NMFPs was assessed by the Digital Reading Department of the Eye Hospital of Wenzhou Medical University. Generalised estimating equations and logistic regression models identified factors affecting image quality.

RESULTS

A total of 17 232 photographs of 8616 subjects were assessed. Of these, 11.9% of images were reliable for the right eyes, while only 4.6% were reliable for the left eyes; 93.6% of images were readable in the right eyes, while 90.3% were readable in the left eyes. In adjusted models, older age was associated with decreased odds of image readability (adjusted OR (aOR)=1.07, 95% CI 1.06~1.08, p<0.001). A larger absolute value of spherical equivalent significantly decreased the odds of image readability (all p<0.001). Media opacity and worse visual acuity had a significantly lower likelihood of achieving readable NMFPs (aOR=1.52, 95% CI 1.31~1.75; aOR=1.70, 95% CI 1.42~2.02, respectively, all p<0.001). Astigmatism axes within 31°~60° and 121°~150° had lower odds of image readability (aOR=1.35, 95% CI 1.11~1.63, p<0.01) than astigmatism axes within 180°±30°.

CONCLUSIONS

The image readability of NMFPs in large-scale glaucoma screening for individuals 50 years and older is comparable with relevant studies, but image reliability is unsatisfactory. Addressing the associated factors may be vital when implementing ophthalmological telemedicine in underserviced areas.

TRIAL REGISTRATION NUMBER: ChiCTR2200059277.

Для цитирования: Chen Qi, Zhou Mengtian, Cao Yang, Zheng Xuanli, Mao Huiyan, Lei Changrong, Lin Wanglong, Jiang Junhong, Chen Yize, Song Di, Xu Xiang, Ye Cong, Liang Yuanbo. Quality assessment of non-mydriatic fundus photographs for glaucoma screening in primary healthcare centres: a real-world study.. BMJ open ophthalmology. 2023. DOI: 10.1136/bmjophth-2023-001493.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.