Медицинская библиотека · Journal of cataract and refractive surgery · 2024

Comparison of the effect of capsular bend on the rotational stability between 2 toric intraocular lenses.

Wang Yiyi, Lou Xicong, Qian Shuyi, Li Yuanyuan, Wu Xueer, Li Siyan, Wang Yalan, Zhao Yune, Chang Pingjun

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the effect of capsular bend on the rotational stability between 2 toric intraocular lenses (IOLs).

SETTING

Eye Hospital of Wenzhou Medical University, Hangzhou, Zhejiang Province, China.

DESIGN

Prospective study.

METHODS

Patients with preexisting astigmatism received AcrySof IQ (SN6AT) or TECNIS (ZCT/ZMT) toric IOL during cataract surgery. CASIA2 was used to record the toric IOL axial orientation and capsular bend index (CBI) at the 1-day, 1-week, 1-month, and 3-month interval postoperatively. The postoperative rotational stability and CBI of both models were compared.

RESULTS

A total of 58 eyes from 58 patients were enrolled in this study. The total misalignment of the TECNIS (ZCT/ZMT) group (6.96 ± 5.10 degrees, 7.41 ± 5.19 degrees, 6.93 ± 5.29 degrees, and 6.86 ± 5. 27 degrees) was significantly higher than that of the AcrySof IQ (SN6AT) group (3.55 ± 2.21 degrees, 4.00 ± 2.74 degrees, 3.72 ± 2.72 degrees, and 3.52 ± 2.50 degrees) at all follow-up intervals ( P < .05). The mean rotation of the TECNIS (ZCT/ZMT) group (2.66 ± 2.18 degrees) was significantly greater than that of the AcrySof IQ (SN6AT) group (1.65 ± 1.47 degrees) from 1 day to 1 week postoperatively ( P < .05). The capsular bend formation in the TECNIS (ZCT/ZMT) group was delayed compared with the AcrySof IQ (SN6AT) group ( P < .05, at the 1-week, 1-month, and 3-month interval). The TECNIS (ZCT/ZMT) group showed fibrosis in the peripheral anterior capsule, leading to its stretching away from the IOL surface, while the AcrySof IQ (SN6AT) group exhibited gentle adherence of the anterior capsule to the IOL surface.

CONCLUSIONS

The AcrySof IQ toric IOL (SN6AT) exhibited greater rotational stability than the TECNIS toric IOL (ZCT/ZMT), which may partially result from the delay in capsular bend formation of TECNIS at the 1-day to 1-week follow-up postoperatively.

Для цитирования: Wang Yiyi, Lou Xicong, Qian Shuyi, Li Yuanyuan, Wu Xueer, Li Siyan, Wang Yalan, Zhao Yune, Chang Pingjun. Comparison of the effect of capsular bend on the rotational stability between 2 toric intraocular lenses.. Journal of cataract and refractive surgery. 2024. DOI: 10.1097/j.jcrs.0000000000001373.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.