Impact of the preoperative cylinder on astigmatism correction in femtosecond lenticule extraction (FLEX): a prospective observational study.

Mao Xiuyu, Chen Han, Zhao Yinzhen, Ji Shunmei, Dai Jinhui

Наблюдательное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the impact of the preoperative manifest cylinder on astigmatism correction via femtosecond lenticule extraction (FLEX), or small incision lenticule extraction (SMILE).

METHODS

This was a prospective observational study. Eyes were categorized into mild (n = 88), moderate (n = 46), and severe (n = 53) astigmatism groups, based on the preoperative manifest cylinder. Vector analysis was conducted with the back vertex distance set at 12 mm. The primary outcome was the correction index (CI), with secondary outcomes including the safety, efficacy, predictability, and vectoral alterations related to FLEX.

RESULTS

The average target-induced astigmatism was 0.45 ± 0.20 D, 0.95 ± 0.17 D, and 1.99 ± 0.65 D in the three groups (P < 0.001), and the average CI was 1.12± 0.05, 1.01 ± 0.03, and 0.95 ± 0.02 (P = 0.020), with the severe astigmatism group displaying a notably lower CI. The efficacy, safety, predictability, or stability of FLEX did not demonstrate any significant differences among the three groups. The CIs exhibited a significant difference in eyes with with-the-rule (WTR) astigmatism and against-the-rule (ATR) astigmatism from the mild to severe astigmatism group. In eyes with oblique astigmatism, the average CI exceeded one.

CONCLUSION

Patients with manifest cylinder exceeding 1.25 D have a heightened risk of under-correction in WTR and ATR astigmatism compared to those with mild astigmatism, and mild over-correction may occur in cases of oblique astigmatism.

Для цитирования: Mao Xiuyu, Chen Han, Zhao Yinzhen, Ji Shunmei, Dai Jinhui. Impact of the preoperative cylinder on astigmatism correction in femtosecond lenticule extraction (FLEX): a prospective observational study.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2023. DOI: 10.1007/s00417-023-06211-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.