[Application of intraoperative optical coherence tomography in deep lamellar keratoplasty].

Wang X, Qi X L, Wang M L, Su M, Li S X, Shi W Y, Gao H

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

Objective

To evaluate the clinical application value of intraoperative optical coherence tomography (iOCT) in deep anterior lamellar keratoplasty (DALK) using the big-bubble technique to bare Descemet's membrane.

Methods

Retrospective case series. Clinical data of 92 patients (92 eyes) with monocular stromal corneal diseases who underwent big-bubble DALK in the Eye Hospital of Shandong First Medical University from January 2020 to August 2021 were collected. There were 53 males and 39 females. The average age was (53.2±16.0) years old. All patients underwent iOCT scanning to determine the location and depth of the injection needle after initial removal of the corneal lesion, to observe the integrity of the recipient bed, Descemet's membrane, after complete lesion removal, and to observe the adhesion between the corneal graft and the recipient bed and check folds on the recipient bed after suturing of the corneal graft. The intraoperative perforation of Descemet's membrane, postoperative thickness of the cornea and the recipient bed, visual acuity, and corneal astigmatism were recorded.

Results

By iOCT, the thickness of the recipient bed was found to be about 1/2 of the corneal thickness and relatively uniform in all directions in 62 eyes (67.4%), so the sterile air was injected from the center of the recipient bed to separate it from the stromal layer. In 30 eyes (32.6%) with an uneven thickness of the recipient bed, the sterile air was injected from the paracentral area of the recipient bed. Under the guidance of iOCT scanning, 89 eyes (96.7%) did not experience any perforation of Descemet's membrane during surgery. The Descemet's membrane folds in the central 5-mm area of the recipient bed was observed and flattened in 20 eyes with the assistance of iOCT scanning. The postoperative corneal thickness was (578.95±108.26) μm, and the recipient bed thickness was (36.06±23.11) μm. The best corrected visual acuity of all patients at 6 months after surgery was 0.57±0.25 logMAR, which was significantly better than that before surgery (1.61±1.27 logMAR; P<0.001). The average corneal astigmatism at 6 months after surgery was (2.72±2.44) diopters.

Conclusions

The application of iOCT scanning in DALK surgery assisted by the big-bubble method can provide safe guidance for surgeons to adopt correct surgical procedures, decrease the risk of Descemet's membrane perforation, reduce the recipient bed folds, and facilitate corneal interlayer adhesion, thereby improving the visual prognosis.

Для цитирования: Wang X, Qi X L, Wang M L, Su M, Li S X, Shi W Y, Gao H. [Application of intraoperative optical coherence tomography in deep lamellar keratoplasty].. [Zhonghua yan ke za zhi] Chinese journal of ophthalmology. 2023. DOI: 10.3760/cma.j.cn112142-20230130-00034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.