DOI 10.18240/ijo.2023.08.07

Медицинская библиотека · International journal of ophthalmology · 2023

Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery.

Buhl Lara, Langer Julian, Kassumeh Stefan, Kreutzer Thomas C, Mayer Wolfgang J, Priglinger Siegfried G

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To evaluate the postoperative intraocular lens (IOL) rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.

METHODS

In this retrospective case series, 32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter (D). A plate haptic toric IOL (AT Torbi 709M, Carl Zeiss Meditec AG) was implanted in all eyes. The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity (BCVA).

RESULTS

Preoperative refractive astigmatism was 2.14±1.17 D, which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period (0.67±0.44 D at three months and 0.75±0.25 D at six months; for all groups: P<0.0001 compared to baseline). BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery (P=0.02). Mean IOL axis deviation from the target axis was 3.4°±2.9° after six to eight weeks and significantly decreased over time (2.4°±2.6° six months after surgery; P=0.04). In one patient IOL, re-alignment was performed.

CONCLUSION

Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery. The plate haptic toric IOL position and axis remain stable during the observation period of six months.

Для цитирования: Buhl Lara, Langer Julian, Kassumeh Stefan, Kreutzer Thomas C, Mayer Wolfgang J, Priglinger Siegfried G. Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery.. International journal of ophthalmology. 2023. DOI: 10.18240/ijo.2023.08.07.