m+Medelevator.RU
← Поиск публикаций
Journal of refractive surgery (Thorofare, N.J. : 1995) · 2023

Efficacy Comparison Between Toric Posterior Chamber Phakic IOL and Posterior Chamber Phakic IOL Plus Modified Steep Meridian Corneal Relaxing Incision for Moderate to High Astigmatism Corrections.

Рандомизированное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Liu Shengtao, Wang Xuejun, Chen Xun, Wang Xiaoying, Zhao Jing, Zhou Xingtao

Аннотация

PURPOSE: To compare posterior chamber phakic intraocular lens (Implantable Collamer Lens [STAAR Surgical]) (ICL) plus modified steep meridian corneal relaxing incision (MS-CRI) to toric posterior chamber phakic intraocular lens (Toric Implantable Collamer Lens [STAAR Surgical]) (TICL) implantation for the correction of moderate to high astigmatism.

METHODS: In this prospective, randomized clinical trial, patients with myopia who had moderate to high astigmatism (200 eyes) were enrolled and divided into TICL (n = 100) and MSCRI (n = 100) groups. All patients underwent examinations for uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and subjective refraction before surgery and at the 1- and 6-month follow-up visits. Vector astigmatism analysis was evaluated using the Alpins method.

RESULTS: The mean UDVA and CDVA demonstrated significant improvement after surgery in both groups. During the 6-month follow-up, the MS-CRI group showed a slight regression tendency (P < .001) and the TICL group was stable for the astigmatism correction (P = .510). At 6 months postoperatively, the mean magnitudes of the surgically induced astigmatism were 1.46 ± 0.53 and 1.10 ± 0.48 diopters (P < .001). The correction index of the TICL group was closer to 1 compared to that of the MS-CRI group (0.95 vs 0.76). Approximately 99% of eyes in the TICL group had angle of error within ±15°, whereas 89% eyes in the MS-CRI group were within that range. A significant relationship between the magnitudes of target induced astigmatism and correction index was noted in the MS-CRI group (P < .001), but not in the TICL group (P = .592).

CONCLUSIONS: TICL implantation could achieve better visual outcomes for correcting moderate to high astigmatism compared to ICL implantation plus MS-CRI. [J Refract Surg. 2023;39(8):539-545.].

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты