m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2023

Characteristics of surgically induced astigmatism after standardized microincisional cataract surgery with a superior limbal incision.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wendelstein Jascha, Casazza Marina, Riaz Kamran M, Fischinger Isaak, Fuchs Barbara, Bolz Matthias, Seiler Theo G, Kohnen Thomas, Langenbucher Achim

Аннотация

PURPOSE: To determine (1) if measurements of surgically induced astigmatism (SIA) as measured by keratometry (K) and total keratometry (TK) differ (2) if SIA affects the magnitude and/or meridian of keratometric astigmatism (3) if SIA evolves over time.

SETTING: Tertiary care center.

DESIGN: Retrospective data analysis.

METHODS: A swept-source optical coherence tomography biometry dataset (IOLMaster700) consisting of 498 eyes (327 patients) from a tertiary care center was analyzed. For all eyes preoperative and postoperative biometric measurements at 1-month, 3-month, and 6-months postoperative visits were considered for vector analysis of SIA K and SIA TK .

RESULTS: Centroids in right and left eyes were 0.26 diopters (D) @5 degrees/0.31 D @1 degree for SIA K and 0.27 D @4 degrees/0.34 D @1 degree for SIA TK . Centroids for difference vectors K-TK in right and left eyes were 0.02 D @ 176 degrees/0.03 D @6 degrees. The mean SIA magnitudes in right and left eyes were 0.48 ± 0.41 D and 0.50 ± 0.37 D for SIA K and 0.53 ± 0.42 D and 0.54 ± 0.40 D for SIA TK . In eyes with ATR astigmatism, an increase in postoperative astigmatism magnitude was more common than a decrease. More than 30% of eyes showed changes in the meridian of more than 15 degrees.

CONCLUSIONS: Overall, we observed differences in K- and TK-derived SIA, and changes in SIA magnitude over time. For postsurgical interventions, postoperative astigmatism meridian values should be measured to base treatments. Astigmatism magnitude showed a tendency to decrease for steep-meridian incisions and to increase in flat-meridian incisions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты