MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001271

Медицинская библиотека · Journal of cataract and refractive surgery · 2023

Characteristics of surgically induced astigmatism after standardized microincisional cataract surgery with a superior limbal incision.

Wendelstein Jascha, Casazza Marina, Riaz Kamran M, Fischinger Isaak, Fuchs Barbara, Bolz Matthias, Seiler Theo G, Kohnen Thomas, Langenbucher Achim

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine (1) if measurements of surgically induced astigmatism (SIA) as measured by keratometry (K) and total keratometry (TK) differ (2) if SIA affects the magnitude and/or meridian of keratometric astigmatism (3) if SIA evolves over time.

SETTING

Tertiary care center.

DESIGN

Retrospective data analysis.

METHODS

A swept-source optical coherence tomography biometry dataset (IOLMaster700) consisting of 498 eyes (327 patients) from a tertiary care center was analyzed. For all eyes preoperative and postoperative biometric measurements at 1-month, 3-month, and 6-months postoperative visits were considered for vector analysis of SIA K and SIA TK .

RESULTS

Centroids in right and left eyes were 0.26 diopters (D) @5 degrees/0.31 D @1 degree for SIA K and 0.27 D @4 degrees/0.34 D @1 degree for SIA TK . Centroids for difference vectors K-TK in right and left eyes were 0.02 D @ 176 degrees/0.03 D @6 degrees. The mean SIA magnitudes in right and left eyes were 0.48 ± 0.41 D and 0.50 ± 0.37 D for SIA K and 0.53 ± 0.42 D and 0.54 ± 0.40 D for SIA TK . In eyes with ATR astigmatism, an increase in postoperative astigmatism magnitude was more common than a decrease. More than 30% of eyes showed changes in the meridian of more than 15 degrees.

CONCLUSIONS

Overall, we observed differences in K- and TK-derived SIA, and changes in SIA magnitude over time. For postsurgical interventions, postoperative astigmatism meridian values should be measured to base treatments. Astigmatism magnitude showed a tendency to decrease for steep-meridian incisions and to increase in flat-meridian incisions.

Для цитирования: Wendelstein Jascha, Casazza Marina, Riaz Kamran M, Fischinger Isaak, Fuchs Barbara, Bolz Matthias, Seiler Theo G, Kohnen Thomas, Langenbucher Achim. Characteristics of surgically induced astigmatism after standardized microincisional cataract surgery with a superior limbal incision.. Journal of cataract and refractive surgery. 2023. DOI: 10.1097/j.jcrs.0000000000001271.