Outcomes of toric intraocular lens realignment surgery done using slit-lamp method and wavefront aberrometry method.

Prasad R Senthil, Sankarananthan R, Pai Aruna, Kamble Nikhil R, Balakrishnan Logesh, Chitradevi R, Shekhar Madhu

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the slit-lamp method and wavefront aberrometry method based on outcomes of toric realignment surgeries.

SETTINGS: Tertiary care ophthalmic hospital.

DESIGN

Retrospective study.

METHODS

This study included all eyes undergoing toric intraocular lens (TIOL) realignment surgery between January 2019 and December 2021 for which TIOL axis assessment by slit-lamp method and wavefront aberrometry method was available. Data were retrieved from electronic medical records, and we documented demographics, uncorrected visual acuity (UCVA), subjective refraction, and TIOL axis by slit-lamp and wavefront aberrometry methods on postoperative day 1 and day 14. In patients with misalignment, TIOL was realigned to the original position in group 1 (27 patients) and to an axis based on calculations provided by wavefront aberrometer in group 2 (25 patients). Post-realignment surgery, UCVA, subjective refraction, and TIOL axis by slit-lamp and wavefront aberrometry methods were assessed and analyzed.

RESULTS

We analyzed 52 eyes and found that the mean preoperative misalignment with the slit-lamp method (44.9° ±20.0°) and wavefront aberrometry (47.1° ±19.5°) was similar. The corresponding degrees of misalignment post-TIOL repositioning surgeries were 5.2° ±5.2° (slit-lamp method) and 4.7° ±5.1° (wavefront aberrometry) (P = 0.615). Both groups showed significant improvement in median log of minimum angle of resolution (logMAR) UCVA and reduction in median refractive cylinder.

CONCLUSIONS

Slit-lamp method is as good as wavefront aberrometer method to assess TIOL axis. Toric realignment surgery is found to be safe, and realigning TIOL based on either slit-lamp method or wavefront aberrometer method equally improved UCVA and decreased residual refractive cylinder.

Для цитирования: Prasad R Senthil, Sankarananthan R, Pai Aruna, Kamble Nikhil R, Balakrishnan Logesh, Chitradevi R, Shekhar Madhu. Outcomes of toric intraocular lens realignment surgery done using slit-lamp method and wavefront aberrometry method.. Indian journal of ophthalmology. 2023. DOI: 10.4103/ijo.ijo_37_23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.