m+Medelevator.RU
← Поиск публикаций
Journal of clinical medicine · 2023

One-Year Results of Photorefractive Keratectomy for Myopia and Compound Myopic Astigmatism with 210 nm Wavelength All Solid-State Laser for Refractive Surgery.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Roszkowska Anna M, Tumminello Giuseppe, Licitra Carmelo, Severo Alice A, Inferrera Leandro, Camellin Umberto, Schiano-Lomoriello Domenico, Aragona Pasquale

Аннотация

BACKGROUND: To examine the 12-month clinical and refractive outcomes of PRK performed with a UV all-solid-state laser.

METHODS: The study included healthy patients with myopia and/or compound myopic astigmatism enrolled for refractive surgery and treated with PRK using a 210 nm wavelength, 2 kHz repetition rate, UV all-solid-state laser (LaserSoft, Katana Technologies GmbH, Kleinmachnow, Germany). All subjects were examined at baseline and after 1, 3, 6, and 12 months after the treatment with a slit lamp, refraction, visual acuity assessment (logMAR chart), tonometry, ophthalmoscopy, and corneal tomography with a Scheimpflug camera. The outcome measures considered were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, central corneal thickness, and transparency. The efficacy, safety, predictability, and stability were determined.

RESULTS: The study included 34 eyes of 19 patients. The mean UDVA changed from 1.20 ± 0.43 to -0.05 ± 0.10 logMAR at 12 months, and the mean CDVA changed from -0.03 ± 0.06 to -0.06 ± 0.09 logMAR, respectively. The mean spherical equivalent (SE) changed from -4.90 ± 2.12 D to -0.01 ± 0.40 D and was within ±0.50 D of the intended correction in 91% of eyes and within ±1.00 D in 97% of eyes at 12 months. No eyes lost lines of visual acuity, and 64% of eyes gained one or more lines.

CONCLUSIONS: PRK with the 210 nm wavelength, 2 kHz repetition rate, all-solid-state laser LaserSoft system proved to have good visual, refractive, and clinical outcomes after the follow-up at 12 months. The emerging gas-free, solid-state technology might be considered a valid alternative for the gas operating lasers for corneal refractive surgery.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты