DOI 10.1097/j.jcrs.0000000000001254
Evaluation of long-term clinical outcomes after toric implantable collamer lens implantation.
Аннотация
PURPOSE: To evaluate the long-term (8-10 years) outcomes of toric implantable collamer lens (TICL) surgery.
SETTING
Nagoya Eye Clinic, Nagoya, Aichi, Japan.
DESIGN
Retrospective observational study.
METHODS
Patients who underwent TICL surgery from 2005 to 2009 to correct myopia and myopic astigmatism were enrolled. The safety, efficacy, predictability, astigmatism correction efficacy, and complications were evaluated using preoperative, 1-year postoperative, and final examination data.
RESULTS
133 eyes of 77 patients were included. At the final visit, the mean uncorrected and corrected visual acuities were -0.01 ± 0.2 and -0.17 ± 0.05, respectively. The mean safety and efficacy indices were 0.91 ± 0.26 and 0.68 ± 0.21, respectively. The manifest astigmatism was -0.45 ± 0.43 diopters (D). The mean corneal astigmatism change from 1 year postoperatively to the final visit was 0.40 ± 0.26 D. Of the 38 eyes with a change in corneal astigmatism ≥0.5 D, 30 eyes (78.9%) changed to against-the-rule (ATR) astigmatism, 1 (2.6%) changed to oblique astigmatism, and 7 (18.4%) changed to with-the-rule (WTR) astigmatism. The mean manifest astigmatism change from 1 year postoperatively to the final visit was 0.43 ± 0.52 D. Of the 60 eyes with a change in manifest astigmatism ≥0.5 D, 25 (41.7%) changed to ATR astigmatism, 18 (30.0%) changed to oblique astigmatism, and 17 (28.3%) changed to WTR astigmatism. During follow-up, 8 (6.0%) of 133 eyes developed anterior subcapsular cataracts, among which 4 (3.0%) underwent TICL removal and phacoemulsification and aspiration. No vision-threatening complications occurred.
CONCLUSIONS
TICL surgery showed good long-term astigmatism-correcting effects, although the long-term uncorrected visual acuity decreased. The procedure was effective in correcting myopia and astigmatism.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.