MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2023/7911449

Медицинская библиотека · Journal of ophthalmology · 2023

The Impact of Angle Lambda on Patient Satisfaction after Optiflex Trio Trifocal Intraocular Lens Implantation.

Kaya Ünsal Sultan, Sunay Ertan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the vision-related quality of life (QOL), visual acuities, and refractive outcomes of patients with different angle lambda (λ) after a trifocal intraocular lens (IOL) implantation at Veni Vidi Eye Hospital, İstanbul, Turkey.

METHODS

This retrospective, nonrandomized, and noncomparative case series included patients who had phacoemulsification bilaterally with the implantation of a trifocal IOL (Optiflex Trio) and responded to a vision-related QOL questionnaire measuring patient satisfaction. The patients were divided into two groups according to the angle λ with a cutoff value of 0.5 mm. Evaluations were conducted to examine the monocular visual acuities, spherical equivalents, corneal astigmatism measured 3 months after surgery, and outcomes of the QOL questionnaire in the two groups.

RESULTS

The study examined 130 eyes from 65 patients aged from 41 to 78 years old. There were no statistically significant differences between the two groups at 3 months after surgery in terms of uncorrected distance visual acuity (UDVA), monocular uncorrected intermediate visual acuity (UIVA), monocular uncorrected near visual acuity (UNVA), spherical equivalent, and corneal astigmatism (P > 0.05). Patients with a greater angle λ had significantly more difficulty going out to see movies, plays, or sporting events (P=0.02), driving at night (P=0.002), and driving in difficult conditions (P < 0.001) than patients with a lower angle λ.

CONCLUSIONS

The Optiflex Trio showed good results in terms of visual acuity at all distances, positive refractive outcomes, and high patient satisfaction in daily life according to the QOL questionnaire. An angle λ greater than 0.5 mm may potentially cause dysphotopsia symptoms, especially during nighttime activities.

Для цитирования: Kaya Ünsal Sultan, Sunay Ertan. The Impact of Angle Lambda on Patient Satisfaction after Optiflex Trio Trifocal Intraocular Lens Implantation.. Journal of ophthalmology. 2023. DOI: 10.1155/2023/7911449.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.