DOI 10.3390/diagnostics14020142
Patient Radiation Exposure during Enteroscopy-Assisted Endoscopic Retrograde Cholangiopancreatography in Surgically Altered Anatomy (with Video).
Аннотация
BACKGROUND
Fluoroscopy must be used cautiously during endoscopic retrograde cholangiopancreatography (ERCP). Radiation exposure data in patients with surgically altered anatomy undergoing enteroscopy-assisted ERCP (EA-ERCP) are scarce.
METHODS
34 consecutive EA-ERCP procedures were compared with 68 conventional ERCP (C-ERCP) procedures. Patient and procedure characteristics and radiation data were collected.
RESULTS
Surgical reconstructions were gastrojejunostomy, Roux-en-Y hepaticojejunostomy, Roux-en-Y total gastrectomy, Roux-en-Y gastric bypass and Whipple's duodenopancreatectomy. Procedures were restricted to biliary indications. Mean fluoroscopy time was comparable in both groups (370 ± 30 s EA-ERCP vs. 393 ± 40 s C-ERCP, p = 0.7074), whereas total mean radiation dose was lower in EA-ERCP (83 ± 6 mGy) compared to C-ERCP (110 ± 11 mGy, p = 0.0491) and dose area product (DAP) was higher in EA-ERCP (2216 ± 173 µGy*m2) compared to C-ERCP (1600 ± 117 µGy*m2, p = 0.0038), as was total procedure time (77 ± 5 min vs. 39 ± 3 min, p < 0.0001). Enteroscope insertion to reach the bile duct during EA-ERCP took 28 ± 4 min, ranging from 4 to 90 min. These results indicate that C-ERCP procedures are generally more complex, needing magnified fluoroscopy, whereas EA-ERCP procedures take more time for enteroscope insertion under wide field fluoroscopic guidance (increased DAP) with less complex ERCP manipulation (lower total radiation dose).
CONCLUSIONS
Radiation exposure during EA-ERCP in surgically altered anatomy is different as compared to C-ERCP. EA-ERCP takes longer with a higher DAP because of the enteroscope insertion, but with lower total radiation dose because these ERCP procedures are usually less complex.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.