MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11695-022-06238-y

Медицинская библиотека · Obesity surgery · 2022

Safety and Efficacy of Trocar Port-Site Closure Using a Biological Plug Closure in Laparoscopic Bariatric Surgery: a Prospective Study.

Andraos Youssef

СтатьяОбзорПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Port-site trocar closure is a challenging procedure in laparoscopic surgeries, especially in morbidly obese patients, and complications (herniation, bleeding, pain, and nerve trapping) have potentially severe consequences. This paper provides an overview of existing techniques of suturing and closure in intra-abdominal laparoscopic surgery, outlines the complications associated with port-site closure, and presents a novel technique designed to address those problems by using a sterile absorbable gelatin sponge with strong hemostatic properties (Cutanplast® Plug).

MATERIALS AND

METHODS

In this prospective study, 83 successive obese patients undergoing laparoscopic bariatric surgery (sleeve gastrectomy, sleeve plication, gastric bypass), using a standardized skin incision for trocar insertion, had port-site closure using the Cutanplast plug procedure (n = 42) or conventional suturing techniques (n = 41).

RESULTS

The incidence of early complications was lower in the Cutanplast group; no patients had infections compared with 9.8% of Controls (p = 0.055) and no bleeding, ecchymosis, erythema, or redness occurred. Late complications during 2 years of follow-up were significantly lower in the Cutanplast group (0 vs. 7 hernias, p = 0.005). Most patients in the Cutanplast group required only 1-2 procedures (78.6% vs. 58.5%, p = 0.049), whereas 41.5% of controls required 3 procedures. In total, 82 trocars were used in the Cutanplast group versus 99 in controls. The single-step Cutanplast plug technique reduced operating times compared with two-step suturing techniques.

CONCLUSION

Closure of port-site trocar incisions using Cutanplast plug is fast, efficient, with potential to reduce operating times and decrease bleeding and herniation from port-site trocars insertion, particularly in obese patients.

Для цитирования: Andraos Youssef. Safety and Efficacy of Trocar Port-Site Closure Using a Biological Plug Closure in Laparoscopic Bariatric Surgery: a Prospective Study.. Obesity surgery. 2022. DOI: 10.1007/s11695-022-06238-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.