MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1128/spectrum.00307-24

Медицинская библиотека · Microbiology spectrum · 2024

Evaluation of Xpert point-of-care assays for detection of HIV infection in persons using long-acting cabotegravir for pre-exposure prophylaxis.

Fogel Jessica M, Piwowar-Manning Estelle, Moser Amber, Hill Tinia, Ahmed Shahnaz, Cummings Vanessa, Mostafa Heba H, Wang Zhe, Jennings Andrea, Gallardo-Cartagena Jorge A, Figueroa María Inés, St Clair Marty, Rinehart Alex R, Adeyeye Adeola, Rooney James F, Cohen Myron S, Grinsztejn Beatriz, Landovitz Raphael J, Eshleman Susan H, HPTN 083 Study Team

СтатьяПеревод в очереди

Аннотация

UNLABELLED: Detection of HIV infection may be challenging in persons using long-acting cabotegravir (CAB-LA) pre-exposure prophylaxis (PrEP) due to viral suppression and reduced/delayed antibody production. We evaluated two point-of-care tests for detecting HIV infection in persons who received CAB-LA in the HPTN 083 trial. Samples were obtained from 12 participants who received CAB-LA and had delayed detection of HIV infection using HIV rapid tests and an antigen/antibody test (52 plasma samples; 18 dried blood spot [DBS] samples). Plasma samples were tested with the Xpert HIV-1 Viral Load XC test (Xpert VL-XC); DBS samples were tested with the total nucleic acid Xpert HIV-1 Qual XC test (Xpert Qual-XC). Results from these assays were compared to results from three reference, laboratory-based, plasma RNA assays (Aptima HIV-1 Qualitative assay [Aptima Qual]; Aptima HIV-1 Quant DX Assay [Aptima Quant]; cobas HIV-1/HIV-2 Qualitative Test [cobas]). HIV RNA was detected with all four plasma assays for all samples with viral loads (VLs) ≥ 200 copies/mL; the number of samples with VLs < 200 copies/mL with HIV RNA detected was: Xpert VL-XC: 19/26 (73.1%); Aptima Qual: 17/26 (65.4%); Aptima Quant: 17/26 (65.4%); and cobas: 12/21 (57.1%). The Xpert Qual-XC assay was positive for all DBS samples with VLs ≥ 200 copies/mL and 1/10 DBS with VLs < 200 copies/mL. The performance of the Xpert VL-XC assay was comparable to the reference assays for detecting HIV infection in these cases. The Xpert Qual-XC assay was less sensitive than plasma-based HIV RNA assays for detecting HIV in the setting of CAB-LA PrEP.

IMPORTANCE

HIV RNA assays can detect HIV infections earlier than HIV rapid tests or Ag/Ab tests in persons using CAB-LA PrEP. Earlier HIV diagnosis could allow for earlier treatment initiation and reduced risk of INSTI resistance. POC tests may help detect HIV infection before CAB-LA administration and may be more accessible than laboratory-based assays in some settings. In this study, the POC Xpert VL-XC assay detected HIV RNA in most samples from individuals who received CAB-LA PrEP and had delayed detection of HIV infection with HIV rapid tests and an Ag/Ab test. The performance of this assay was similar to laboratory-based HIV RNA assays in this cohort. The POC Xpert Qual-XC assay detects both HIV RNA and DNA, with a higher viral load cutoff for RNA detection. This assay was negative for most lower viral load samples and did not offer an advantage for HIV screening in persons using CAB-LA PrEP.

Для цитирования: Fogel Jessica M, Piwowar-Manning Estelle, Moser Amber, Hill Tinia, Ahmed Shahnaz, Cummings Vanessa, Mostafa Heba H, Wang Zhe, Jennings Andrea, Gallardo-Cartagena Jorge A, Figueroa María Inés, St Clair Marty, Rinehart Alex R, Adeyeye Adeola, Rooney James F, Cohen Myron S, Grinsztejn Beatriz, Landovitz Raphael J, Eshleman Susan H, HPTN 083 Study Team. Evaluation of Xpert point-of-care assays for detection of HIV infection in persons using long-acting cabotegravir for pre-exposure prophylaxis.. Microbiology spectrum. 2024. DOI: 10.1128/spectrum.00307-24.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.