MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/neurolint16050074

Медицинская библиотека · Neurology international · 2024

Fluorescein Angiography for Monitoring Neural Blood Flow in Chronic Nerve Compression Neuropathy: Experimental Animal Models and Preliminary Clinical Observations.

Saito Kosuke, Okada Mitsuhiro, Yokoi Takuya, Hama Shunpei, Nakamura Hiroaki

СтатьяПеревод пока не подготовлен

Аннотация

Pathologies associated with neural blood disturbance have been reported in patients with chronic nerve compression (CNC) neuropathy. Fluorescein angiography (FAG) and laser Doppler flowmetry (LDF) are effective for real-time peripheral nerve blood flow assessment. However, their reliability in severe neuropathy models in large animals or clinical conditions remains unclear. Initially, we aim to apply FAG to two different CNC animal models and evaluate their characteristics in comparison with those of LDF. In FAG, we quantified the peak luminance at the compression site following fluorescein injection. Then, we positioned the LDF probe at the center of the compression site and recorded the blood flow. Subsequently, we analyzed whether the FAG characteristics obtained in this animal experiment were consistent with those of clinical studies in patients with severe carpal tunnel syndrome (CTS). In the CNC rat model, FAG and LDF effectively monitored reduced neural blood flow over time. We observed significant blood flow reduction using both techniques in a newly developed severe CNC rabbit model. Notably, FAG correlated strongly with the compound muscle action potential (CMAP) amplitude in electrodiagnostic findings, unlike LDF. As a next step, we performed FAG after open carpal tunnel release in clinical cases of CTS. FAG correlated significantly with preoperative CMAP amplitude. This indicates FAG's importance for assessing nerve blood flow during surgery, potentially improving diagnostic accuracy and surgical outcomes.

Для цитирования: Saito Kosuke, Okada Mitsuhiro, Yokoi Takuya, Hama Shunpei, Nakamura Hiroaki. Fluorescein Angiography for Monitoring Neural Blood Flow in Chronic Nerve Compression Neuropathy: Experimental Animal Models and Preliminary Clinical Observations.. Neurology international. 2024. DOI: 10.3390/neurolint16050074.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.