MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2459/01.jcm.0000263499.58251.78

Медицинская библиотека · Journal of cardiovascular medicine (Hagerstown, Md.) · 2007

Real-time three-dimensional echocardiography: a pilot feasibility study in an Italian cardiologic center.

Correale Michele, Ieva Riccardo, Balzano Marco, Di Biase Matteo

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The majority of studies demonstrating the diagnostic potential of three-dimensional (3-D) echocardiography have been conducted on selected series of patients in research laboratories.

AIM: To investigate the feasibility and usefulness of real-time 3-D transthoracic echocardiography in daily routine practice.

METHODS

Two hundred consecutive patients underwent standard two-dimensional (2-D) transthoracic echocardiography (TTE) and real-time (RT) 3-D TTE with a commercially available ultrasound system (Sonos 7500 LIVE 3D, Philips Medical Systems). The quality of 3-D acquisitions and post-processed images was graded as: bad, satisfactory, good and demo. In each case, the results of 3-D TTE were compared with 2-D images to disclose additional qualitative information provided by 3-D examination. An additional qualitative information score was given for each cardiac structure.

RESULTS

The mean time of the 3-D examination was 11+/-4 min. The mean time of 2-D transthoracic studies in our laboratory is 25 min and the total time in this series was therefore approximately 36 min. The mean number of acquisitions in our series was 11.5 per patient. The quality was evaluated as bad/insufficient in 7.0%, satisfactory/sufficient in 29.6%, good in 40.2% and demo in 23.2% of all datasets and reconstructions. The structures with greater additional qualitative information scores comprise the anterior and posterior mitralic leaflets, antero-lateral and postero-medial papillary muscles and leaflets of tricuspid valve. The intra- and interobserver reproducibility of quality grading was good and there are few interobserver discrepancies, which were resolved by two physicians, experienced in 3-D echocardiography, not involved in the study.

CONCLUSIONS

RT 3-D TTE may be used in clinical settings with high feasibility rate and may provide additional, clinically quite relevant qualitative information. This technique may expand the abilities of non-invasive cardiology and open new doors for the evaluation of cardiac disease.

Для цитирования: Correale Michele, Ieva Riccardo, Balzano Marco, Di Biase Matteo. Real-time three-dimensional echocardiography: a pilot feasibility study in an Italian cardiologic center.. Journal of cardiovascular medicine (Hagerstown, Md.). 2007. DOI: 10.2459/01.jcm.0000263499.58251.78.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.