BACKGROUND

To evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens.

METHODS

Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined.

RESULTS

For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus and the Random dot sterereotests, the values were 56.40 ± 18.00 and 54.80 ± 20.23 seconds of arc, respectively. For the SCL group, mean stereoacuities were 19.9 ± 4.6, 51.2 ± 16.4 and 51.2 ± 20.88 seconds of arc, with the Howard-Dolman, Titmus and the Random dot, respectively. There were no statistically significant differences among groups for Howard-Dolman (p = 0.07), Titmus (p = 0.10) and Random dot (p = 0.17) stereotests. No statistically significant differences were found between the Titmus and the Random dot stereotest values (multifocal group: p = 0.30 and SCL group: p = 0.50), however, these values differ significantly from those found using the Howard-Dolman method for both groups (p < 0.001). For the multifocal group, BHCVA was -0.007 ± 0.060 and 0.012 ± 0.063 logMAR for distance and near vision, respectively. For the SCL group, these values were -0.02 ± 0.05 and -0.01 ± 0.06 logMAR, for distance and near vision, respectively. Comparing both groups there were no statistically significant differences between groups for either distance (p = 0.08) or near (p = 0.09).

CONCLUSIONS

The Proclear Multifocal contact lens provided good distance and near visual acuity preserving stereopsis. Multifocal optics with one lens biased to distance viewing and the other lens biased toward near viewing minimally affects stereoacuity.

Для цитирования: Ferrer-Blasco Teresa, Madrid-Costa David. Stereoacuity with balanced presbyopic contact lenses.. Clinical & experimental optometry. 2010. DOI: 10.1111/j.1444-0938.2010.00530.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.