MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/112067211002000324

Медицинская библиотека · European journal of ophthalmology · 2010

Refractive lens exchange with the Acri.Twin asymmetric diffractive bifocal intraocular lens system.

Alfonso José F, Fernández-Vega Luis, Ortí Susana, Montés-Micó Robert

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had implantation of asymmetric Acri.Twin bifocal diffractive intraocular lenses.

METHODS

The study comprised 130 eyes of 65 consecutive patients after RLE who had bilateral implantation of the Acri.Twin system. Eyes were divided into myopic and hyperopic groups. Binocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery.

RESULTS

Efficacy indexes were 0.99 for myopic and 0.93 for hyperopic patients at 6 months postoperatively. No patients lost >2 lines of BCVA. For the myopic group, 6 patients gained 1 line, and 10 patients gained >or=2 lines; for the hyperopic group, 5 patients gained 1 line, and 6 patients gained >or=2 lines. Safety indexes were 1.13 and 1.03 for myopic and hyperopic patients, respectively. No patients lost >or=2 lines of BCNVA; for the myopic group, only 2 patients lost 1; for the hyperopic group there was no change after surgery. Safety indexes at near were 0.99 for myopic and 1.00 for hyperopic patients. Efficacy indexes at near were 1.05 for myopic and 1.07 for hyperopic patients.

CONCLUSIONS

RLE with asymmetric bilateral implantation of the Acri.Twin bifocal IOL is an effective procedure for correcting ametropia and presbyopia. Results obtained were safe and effective at distance and near for both myopic and hyperopic patients.

Для цитирования: Alfonso José F, Fernández-Vega Luis, Ortí Susana, Montés-Micó Robert. Refractive lens exchange with the Acri.Twin asymmetric diffractive bifocal intraocular lens system.. European journal of ophthalmology. 2010. DOI: 10.1177/112067211002000324.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.