DOI 10.3928/1081597x-20090115-13
Pseudoaccommodative cornea treatment using the NIDEK EC-5000 CXIII excimer laser in myopic and hyperopic presbyopes.
Аннотация
PURPOSE: To investigate the refractive outcomes and spherical aberration of multifocal LASIK to create a distant-dominant center and near-dominant periphery in hyperopic, myopic, and emmetropic presbyopia.
METHODS
One hundred ninety-five eyes with myopic presbyopia and 119 eyes with hyperopic or emmetropic presbyopia that underwent LASIK or epithelial LASIK (epi-LASIK) were assessed out to 3 months postoperatively. All eyes underwent the pseudoaccommodative cornea (PAC) treatment using aspheric ablation profiles and wavefront correction with the NIDEK CXIII excimer laser. Mean preoperative spherical equivalent refraction was -3.80+/-2.10 diopters (D) for myopic presbyopia and +1.00+/-0.92 D for hyperopic or emmetropic presbyopia.
RESULTS
Mean postoperative spherical equivalent refraction was -0.40+/-0.77 D for myopic presbyopia and +0.15+/-0.62 D for hyperopic or emmetropic presbyopia. Functional vision, defined as 20/30 or better distance uncorrected visual acuity (UCVA) combined with J3 or better near UCVA, was achieved in 162 (83%) eyes with myopic presbyopia and 103 (87%) eyes with hyperopic or emmetropic presbyopia. An induction of 0.312 microm of spherical aberration was noted at 6 mm for myopic presbyopia treatments and 0.016 microm for hyperopic presbyopia treatments.
CONCLUSIONS
The distance-dominant center used for PAC treatments is effective in emmetropic, myopic, and hyperopic presbyopia. The induced spherical aberration allows for depth of focus in patients with presbyopia.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.