MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2008.01.017

Медицинская библиотека · Journal of cataract and refractive surgery · 2008

Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens.

Montés-Micó Robert, Ferrer-Blasco Teresa, Charman W Neil, Cerviño Alejandro, Alfonso José F, Fernández-Vega Luis

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.

SETTING

University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.

METHODS

Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (< or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective distances. Wavefront aberrations were measured before and after surgery. Aberrations for 2 pupil diameters (3.0 mm and 5.0 mm) were decomposed using Zernike polynomials; total, defocus, astigmatism spherical, and coma aberration terms were studied separately. Postimplantation results were compared with preoperative values.

RESULTS

Safety and efficacy indices for distance vision were 1.01 and 0.96, respectively. At near, they improved to 1.07 and 1.06, respectively. Vision at intermediate distances was noticeably poorer. Total, defocus, and spherical aberrations changed after IOL implantation with both pupil diameters (P<.01). Total and defocus aberrations were significantly reduced postoperatively. Spherical aberration coefficients changed to negative and less positive values for a 3.0 mm and a 5.0 mm pupil, respectively.

CONCLUSIONS

Implantation of the pseudoaccommodating IOL in healthy eyes yielded uncorrected levels of high-contrast, distance, and near acuities comparable to preoperative best corrected values. Higher-order aberration levels appeared to be similar to the preoperative values.

Для цитирования: Montés-Micó Robert, Ferrer-Blasco Teresa, Charman W Neil, Cerviño Alejandro, Alfonso José F, Fernández-Vega Luis. Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens.. Journal of cataract and refractive surgery. 2008. DOI: 10.1016/j.jcrs.2008.01.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.