Is randomisation necessary for measuring defocus curves in pre-presbyopes?

Gupta Navneet, Naroo Shehzad A, Wolffsohn James S

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Defocus curves are used to evaluate the subjective range of clear vision of presbyopic corrections such as in eyes implanted with accommodating intraocular lenses (IOLs). This study determines whether letter sequences and/or lens presentation order ought to be randomised when measuring defocus curves.

METHODS

Defocus curves (range +2.00DS to -2.00DS) were measured on 18 pre-presbyopic subjects (mean age 24.1+/-4.2 years) for six combinations of sequential or randomised positive or negative lens progression and non-randomised or randomised letter sequences. The letters were presented on a computerised logMAR chart at 6m.

RESULTS

Overall there was a statistically significant difference between the six combinations (ANOVA, p<0.05) attributable to the combination of non-randomised letters with non-randomised lens progression from negative to positive defocus (p<0.01). There was no statistically significant difference in defocus curve measurements if both letters and lens order were randomised compared to if only one of these variables was randomised (p>0.05). Non-randomised letters, with a sequential lens progression from negative to positive, was significantly different to all other combinations when compared individually (Student's T-test, p<0.003 on all comparisons), and was confirmed as the sole source of the overall significant difference. There was no statistically significant difference if both lens presentation order and letter sequences were randomised compared to if only one or the other of these variables was randomised.

CONCLUSION

Non-randomised letters and non-randomised lens progression on their own did not affect the subjective amplitude of accommodation as measured by defocus curves, although their combination should be avoided.

Для цитирования: Gupta Navneet, Naroo Shehzad A, Wolffsohn James S. Is randomisation necessary for measuring defocus curves in pre-presbyopes?. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2007. DOI: 10.1016/j.clae.2007.02.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.