MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2006.10.058

Медицинская библиотека · Ophthalmology · 2007

Clear lens extraction with multifocal apodized diffractive intraocular lens implantation.

Fernández-Vega Luis, Alfonso José F, Rodríguez Pedro P, Montés-Micó Robert

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation.

DESIGN

Prospective, nonrandomized, masked observational case series (self-controlled).

PARTICIPANTS

Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], -6.01+/-2.71 diopters [D]) and hyperopic (mean SE, +3.86+/-2.52 D) groups.

METHODS

Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recorded preoperatively and 6 months after surgery.

MAIN OUTCOMES MEASURES: Efficacy, safety, predictability, and stability.

RESULTS

At 6 months postoperatively, uncorrected distance VA was 20/25 or better in 100% of the eyes. Efficacy indexes were 0.97 for myopic and 0.96 for hyperopic patients. No eye lost > or =2 lines of best-corrected distance VA; for the myopic group, 10 eyes gained 1 line, and 10 eyes gained > or =2 lines; for the hyperopic group, 20 eyes gained 1 line, and 15 eyes gained > or =2 lines. Safety indexes were 1.05 for myopic and 1.02 for hyperopic patients. All eyes were within +/-1.00 D of the desired refraction. No eye lost >2 lines of best distance-corrected near VA; for the myopic group, 10 eyes lost 1 or 2 lines, 15 eyes gained 1 line, and 5 eyes gained 2 lines; for the hyperopic group, 8 eyes lost 1 or 2 lines, 20 eyes gained 1 line, and 16 eyes gained 2 lines. Safety indexes at near were 1.05 for myopic and 1.11 for hyperopic patients. Uncorrected distance near VA was better for hyperopic than myopic patients (0.95+/-0.08 vs. 0.88+/-0.15). Efficacy indexes at near were 1.03 for myopic and 1.10 for hyperopic patients.

CONCLUSIONS

Clear lens extraction with multifocal IOL implantation is an effective procedure for correcting ametropia and presbyopia. Safety and efficacy indexes at distance were comparable in myopic and hyperopic patients. However, at near, both indexes were larger for hyperopic patients.

Для цитирования: Fernández-Vega Luis, Alfonso José F, Rodríguez Pedro P, Montés-Micó Robert. Clear lens extraction with multifocal apodized diffractive intraocular lens implantation.. Ophthalmology. 2007. DOI: 10.1016/j.ophtha.2006.10.058.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.