MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2006.05.031

Медицинская библиотека · Journal of cataract and refractive surgery · 2006

Magnetic resonance imaging of aging, accommodating, phakic, and pseudophakic ciliary muscle diameters.

Strenk Susan A, Strenk Lawrence M, Guo Suqin

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: To quantify in vivo accommodative changes in the aging human ciliary muscle diameter in phakic and pseudophakic eyes.

SETTING

Department of Surgery/Bioengineering, UMDNJ-Robert Wood Johnson Medical School, Piscataway, and the Institute of Ophthalmology and Visual Science UMDNJ-New Jersey Medical School, Newark, New Jersey, USA.

METHODS

Images were acquired from 48 eyes of 40 people between the ages of 22 and 91 years, 1 eye of 32 phakic volunteers and both eyes of 8 patients who had monocular implantation of a single-piece AcrySof intraocular lens (IOL) (Alcon Laboratories). Images were acquired during physiological accommodation and with accommodation at rest, and the diameter of the ciliary muscle ring was measured.

RESULTS

Results show the ciliary muscle remains active throughout life. The accommodative change in its diameter (mean 0.64 mm) (P<.00001) was undiminished by age or IOL implantation. Preliminary data showed that the accommodative decrease in muscle diameter in phakic and pseudophakic eyes was statistically identical. The phakic eyes had a marked decrease in ciliary muscle diameter with advancing age for both accommodative states (P<.000001 and P<.000001), which did not appear to be altered by IOL implantation. The lens equator was constant with age in the unaccommodated human eye, resulting in decreased circumlental space with advancing age in the phakic eyes.

CONCLUSION

Although the undiminished ability of the ciliary muscle to decrease its diameter with accommodation can be relied on in strategies for presbyopia correction, even in advanced presbyopia, the decreasing circumlental space and its potential effects on zonular tension must also be considered.

Для цитирования: Strenk Susan A, Strenk Lawrence M, Guo Suqin. Magnetic resonance imaging of aging, accommodating, phakic, and pseudophakic ciliary muscle diameters.. Journal of cataract and refractive surgery. 2006. DOI: 10.1016/j.jcrs.2006.05.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.