Ongoing right ventricular hemodynamics in heart failure: clinical value of measurements derived from an implantable monitoring system.

Adamson Philip B, Magalski Anthony, Braunschweig Frieder, Böhm Michael, Reynolds Dwight, Steinhaus David, Luby Allyson, Linde Cecilia, Ryden Lars, Cremers Bodo, Takle Teri, Bennett Tom

Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study examined the characteristics of continuously measured right ventricular (RV) hemodynamic information derived from an implantable hemodynamic monitor (IHM) in heart failure patients.

BACKGROUND

Hemodynamic monitoring might improve the day-to-day management of patients with chronic heart failure (CHF). Little is known about the characteristics of long-term hemodynamic information in patients with CHF or how such information relates to meaningful clinical events.

METHODS

Thirty-two patients with CHF received a permanent RV IHM system similar to a single-lead pacemaker. Right ventricular systolic and diastolic pressures, heart rate, and pressure derivatives were continuously measured for nine months without using the data for clinical decision-making or management of patients. Data were then made available to clinical providers, and the patients were followed up for 17 months. Pressure characteristics during optimal volume, clinically determined volume-overload exacerbations, and volume depletion events were examined. The effect of IHM on hospitalizations was examined using the patients' historical controls.

RESULTS

Long-term RV pressure measurements had either marked variability or minimal time-related changes. During 36 volume-overload events, RV systolic pressures increased by 25 +/- 4% (p < 0.05) and heart rate increased by 11 +/- 2% (p < 0.05). Pressure increases occurred in 9 of 12 events 4 +/- 2 days before the exacerbations requiring hospitalization. Hospitalizations before using IHM data for clinical management averaged 1.08 per patient year and decreased to 0.47 per patient-year (57% reduction, p < 0.01) after hemodynamic data were used.

CONCLUSIONS

Long-term ambulatory pressure measurements from an IHM may be helpful in guiding day-to-day clinical management, with a potentially favorable impact on CHF hospitalizations.

Для цитирования: Adamson Philip B, Magalski Anthony, Braunschweig Frieder, Böhm Michael, Reynolds Dwight, Steinhaus David, Luby Allyson, Linde Cecilia, Ryden Lars, Cremers Bodo, Takle Teri, Bennett Tom. Ongoing right ventricular hemodynamics in heart failure: clinical value of measurements derived from an implantable monitoring system.. Journal of the American College of Cardiology. 2003. DOI: 10.1016/s0735-1097(02)02896-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.