MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/echo.13433

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2017

Detection of early radiotherapy-induced changes in intrinsic myocardial contractility by ultrasound tissue characterization in patients with early-stage breast cancer.

Tuohinen Suvi Sirkku, Skyttä Tanja, Huhtala Heini, Virtanen Vesa, Virtanen Marko, Kellokumpu-Lehtinen Pirkko-Liisa, Raatikainen Pekka

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Increased cardiovascular morbidity and mortality are major late complications after radiotherapy (RT) in the thoracic region. Ultrasound tissue characterization (UTC) is a noninvasive method for the identification of myocardial changes. The aim of this prospective clinical trial was to assess whether the analysis of cyclic variation of integrated backscatter (CVIBS) can detect early RT-induced myocardial alterations.

METHODS

Seventy-three eligible patients with early-stage breast cancer were evaluated before and immediately after adjuvant RT. Twenty and 53 patients had right-sided and left-sided breast cancer, respectively. None of the patients received chemotherapy. Comprehensive echocardiographic examination included three-dimensional (3D) measurements and UTC analysis of the left ventricular (LV) septum and posterior wall.

RESULTS

RT reduced CVIBS in a dose-dependent manner. The mean heart radiation dose over two gray (Gy) reduced the septal CVIBS from 12.0±3.4 to 9.6±2.5 dB (P<.001) and the posterior wall CVIBS from 12.8±2.7 to 11.3±2.4 dB (P=.007). The CVIBS remained unchanged when the mean heart RT dose was below 2 Gy. Multivariate analysis showed an independent association with a change in septal CVIBS and the use of aromatase inhibitor (β=2.986, P=.001) and body mass index (β=-0.241, P=.014). The posterior values were worse with higher mean lung dose (β=-.485, P=.018) and with nonsmoking status (β=-2.411, P=.009). Echocardiography parameters showed increased myocardial mass but conventional measurements of the LV systolic function remained unchanged.

CONCLUSIONS

Cyclic variation of integrated backscatter analysis seems to be a sensitive method to detect early RT-induced myocardial changes. Hence, it may be useful in screening of patients needing closer follow-up.

Для цитирования: Tuohinen Suvi Sirkku, Skyttä Tanja, Huhtala Heini, Virtanen Vesa, Virtanen Marko, Kellokumpu-Lehtinen Pirkko-Liisa, Raatikainen Pekka. Detection of early radiotherapy-induced changes in intrinsic myocardial contractility by ultrasound tissue characterization in patients with early-stage breast cancer.. Echocardiography (Mount Kisco, N.Y.). 2017. DOI: 10.1111/echo.13433.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.