MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12094-015-1371-2

Медицинская библиотека · Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2015

The impact of prostate gland dimension in genitourinary toxicity after definitive prostate cancer treatment with moderate hypofractionation and volumetric modulated arc radiation therapy.

Mazzola R, Fersino S, Fiorentino A, Ricchetti F, Giaj Levra N, Di Paola G, Sicignano G, Naccarato S, Ruggieri R, Alongi F

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To analyze clinical-dosimetric predictors of genitourinary (GU) toxicity in a cohort of prostate cancer (PC) patients treated with moderate hypofractionation and simultaneous integrated boost (SIB) using volumetric modulated arc therapy (VMAT) technique.

MATERIALS AND

METHODS

60 patients were selected. Patients were stratified into low (43 %), intermediate (30 %) and high-risk (27 %) groups. Low-risk patients received 73.5 Gy to PTV1; intermediate-risk received 73.5 Gy to PTV1 and 60 Gy to PTV2; high-risk received 73.5 Gy to PTV1, 60 Gy to PTV2, and 54 Gy to PTV3. All patients were treated in 30 fractions. Androgen deprivation therapy (ADT) was prescribed upfront in intermediate and high-risk categories. Toxicity was scored according to Common Terminology Criteria for Adverse Events v4.0 scoring system.

RESULTS

Median follow-up was 30 months (range 16-36 months). GU acute toxicity was recorded as followS: G0 = 16/60 (27 %), G1 = 18/60 (30 %); G2 = 26/60 (43 %). GU late toxicity was recorded as follows: G0 = 20/60 (34 %); G1 = 29/60 (48 %); G2 = 11/56 (18 %). The risk of acute G2 GU toxicity was three times higher for prostate volume ≥80 cc. In 60 % of the patients with a prostate volume ≥80 cc, the first 3 weeks are at particular risk for toxicity onset. In the late setting, no statistical significance was found between GU toxicity and prostate gland dimension.

CONCLUSION

Prostate volume ≥80 cc resulted a predictive factor of acute G2 GU toxicity, in moderate hypofractionation and volumetric modulated arc radiation therapy for definitive PC.

Для цитирования: Mazzola R, Fersino S, Fiorentino A, Ricchetti F, Giaj Levra N, Di Paola G, Sicignano G, Naccarato S, Ruggieri R, Alongi F. The impact of prostate gland dimension in genitourinary toxicity after definitive prostate cancer treatment with moderate hypofractionation and volumetric modulated arc radiation therapy.. Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico. 2015. DOI: 10.1007/s12094-015-1371-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.