MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Osaka city medical journal · 2013

Diagnostic accuracy of transthoracic and transesophageal echocardiography for the diagnosis of bicuspid aortic valve: comparison with operative findings.

Takeda Hisateru, Muro Takashi, Saito Toshio, Hyodo Eiichi, Ehara Shoichi, Hanatani Akihisa, Shimada Kenei, Suehiro Shigefumi, Yoshiyama Minoru

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Bicuspid aortic valve (BAV) is associated with an increased risk of aortic valve (AV) dysfunction, aortic dissection, and infective endocarditis. Therefore, its accurate diagnosis is critical. The morphological features of AVs are generally evaluated by transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE), however, the difference in the diagnostic capability of these imaging modalities for detecting BAV remains unclear. Here, we compared these 2 methods to determine their accuracy, and to clarify each role in the diagnosis of BAV.

METHODS

This blind study evaluated 126 patients (age, 70.3 +/- 7.8 years) who subsequently underwent AV replacement. The number of AV cusps of each patient was estimated by TTE and TEE and compared to the number of AV written in the operative record. Patients with poor echocardiographic images were not excluded.

RESULTS

Surgical findings showed 97 tricuspid AVs and 29 BAVs. The sensitivity, specificity, and accuracy for the diagnosis of BAV were 61%, 81%, and 77%, respectively, for TTE and 86%, 90%, and 89%, respectively, for TEE. The accuracy of TEE was significantly higher than that of TTE (p = 0.016). In non-calcified AVs, the accuracy of TTE was similar to that of TEE (96%, each) whereas in calcified AVs, TTE had a lower accuracy than TEE (72% vs 87%, p = 0.011). The feasibility was significantly higher for TEE than for TTE (98% vs 90%, p = 0.003).

CONCLUSIONS

TEE provides higher accuracy and feasibility than TTE in the diagnosis of BAV, and it should therefore be indicated when morphological features of AVs cannot be evaluated by TTE.

Для цитирования: Takeda Hisateru, Muro Takashi, Saito Toshio, Hyodo Eiichi, Ehara Shoichi, Hanatani Akihisa, Shimada Kenei, Suehiro Shigefumi, Yoshiyama Minoru. Diagnostic accuracy of transthoracic and transesophageal echocardiography for the diagnosis of bicuspid aortic valve: comparison with operative findings.. Osaka city medical journal. 2013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.