MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2013.08.031

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2013

Hemodynamic outcomes of geometric ring annuloplasty for aortic valve repair: a 4-center pilot trial.

Mazzitelli Domenico, Stamm Christof, Rankin J Scott, Nöbauer Christian, Pirk Jan, Meuris Bart, Crooke Philip S, Wagner Anke, Beavan L Alan, Griffin Charles D, Powers Debby, Nasseri Boris, Schreiber Christian, Hetzer Roland, Lange Rüdiger

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

A geometric annuloplasty ring could improve efficacy and stability of aortic valve repair. Toward this goal, a 1-piece 3-dimensional titanium annuloplasty ring with Dacron covering was developed and tested successfully in animals. The purpose of this study was to define hemodynamic outcomes with this device used as the annuloplasty component of human aortic valve repair.

METHODS

In a 4-center pilot trial with informed consent, 16 patients underwent aortic valve repair for aortic insufficiency, with the annuloplasty device sutured into the annulus beneath the leaflets. Preoperative annular diameter averaged 26.5 ± 2.0 (mean ± standard deviation) mm, and average ring size was 22.3 ± 1.2 mm. After annuloplasty, leaflet defects were easy to identify, and 14 of 16 patients (88%) required leaflet plication and/or autologous pericardial reconstruction for leaflet defects. Three patients had ascending aortic replacement, and 2 had remodeling root replacement. One had ultrasonic leaflet decalcification and another tricuspid valve annuloplasty. Follow-up data were from site-specific studies at the 6-month postoperative time point.

RESULTS

There were no in-hospital mortalities or major complications. Preoperative aortic insufficiency grade (0-4 scale) was 3.6 ± 1.0 and fell to 1.0 ± 0.8 at 6 months (P < .0001). New York Heart Association class fell from 2.5 ± 0.5 to 1.1 ± 0.3 (P < .0001). Postrepair valve area was 2.7 ± 0.2 cm(2), and 6-month mean systolic gradient was 11.3 ± 3.3 mm Hg. Left ventricular end-diastolic diameter and ejection fraction both normalized (both P < .0001).

CONCLUSIONS

Geometric ring annuloplasty facilitated aortic valve repair, allowing more precise reconstruction of leaflet defects. Aortic insufficiency reduction and systolic gradients were excellent, and expansion of valve reconstruction into broader categories of aortic valve disease seems indicated.

Для цитирования: Mazzitelli Domenico, Stamm Christof, Rankin J Scott, Nöbauer Christian, Pirk Jan, Meuris Bart, Crooke Philip S, Wagner Anke, Beavan L Alan, Griffin Charles D, Powers Debby, Nasseri Boris, Schreiber Christian, Hetzer Roland, Lange Rüdiger. Hemodynamic outcomes of geometric ring annuloplasty for aortic valve repair: a 4-center pilot trial.. The Journal of thoracic and cardiovascular surgery. 2013. DOI: 10.1016/j.jtcvs.2013.08.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.