Effect of asymmetry on hemodynamics in fluid-structure interaction model of congenital bicuspid aortic valves.

Marom Gil, Kim Hee-Sun, Rosenfeld Moshe, Raanani Ehud, Haj-Ali Rami

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

A bicuspid aortic valve (BAV) is a congenital cardiac disorder where the valve consists of only two cusps instead of three in a normal tricuspid valve (TAV). Although 97% of BAVs include asymmetric cusps, little or no prior studies investigated the blood flow through physiological three-dimensional BAV and root. This study presents four fully coupled fluid-structure interaction (FSI) models, including native TAV, asymmetric BAV with or without a raphe and an almost symmetric BAV. The FSI simulations are based on coupled structural and fluid dynamics solvers that allow accurate modeling of the pressure load on both the root and the cusps. The partitioned solver has non-conformal meshes and the flow is modeled employing an Eulerian approach. The cusps tissue in the structural model is composed of hyperelastic finite elements with collagen fiber network embedded in the elastin matrix. The tissues behavior of the aortic sinuses is also hyperelastic. The coaptation is modeled with master-slave contact algorithm. A full cardiac cycle is simulated by imposing the same physiological blood pressure at the upstream and downstream boundaries, for all the TAV and BAV models. The latter have significantly smaller opening area compared to the TAV. Larger stress values were also found in the cusps of the BAV models with fused cusps, both at the systolic and diastolic phases. The asymmetric geometry cause asymmetric vortices and much larger wall shear stress on the cusps, which is a potential cause for early valvular calcification in BAVs.

Для цитирования: Marom Gil, Kim Hee-Sun, Rosenfeld Moshe, Raanani Ehud, Haj-Ali Rami. Effect of asymmetry on hemodynamics in fluid-structure interaction model of congenital bicuspid aortic valves.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2012. DOI: 10.1109/embc.2012.6346012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.