Quantitative evaluation of corneal epithelial edema after cataract surgery using corneal densitometry: a prospective study.

Ishikawa Sho, Kato Naoko, Takeuchi Masaru

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The optical density of the cornea can be evaluated quantitatively by "densitometry" using a rotating Scheimpflug camera. Densitometry allows evaluation of corneal opacity in the anterior segment of the eye by quantitative measurement of scattering light. In the present investigation, we evaluate quantitatively minimal subclinical corneal edema after cataract surgery using densitometry.

METHODS

Fifty four eyes of 34 patients who underwent cataract surgery were enrolled. Measurement of corneal density was performed using Pentacam® before and on days 1, 3 and 7 after surgery.

RESULTS

Densitometry scores increased from 18.12 ± 1.76 before cataract surgery to 21.03 ± 3.84 on day 1 (P < 0.001) and 19.90 ± 2.46 on day 3 (P = 0.018), but recovered to 19.44 ± 1.58 on day 7 (P = 0.131). Total corneal thickness was 549.1 ± 32.7 μm before surgery and increased to 582.7 ± 46.3 μm on day 1 (P = 0.001), but recovered to 566.4 ± 29.7 μm on day 3 (P = 0.097). Densitometry reading correlated positively with corneal thickness (correlation coefficient = 0.13, P = 0.003).

CONCLUSIONS

Densitometry is useful to detect corneal edema that is not detectable by slit-lamp examination.

Для цитирования: Ishikawa Sho, Kato Naoko, Takeuchi Masaru. Quantitative evaluation of corneal epithelial edema after cataract surgery using corneal densitometry: a prospective study.. BMC ophthalmology. 2018. DOI: 10.1186/s12886-018-0998-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.