MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3341/kjo.2017.0129

Медицинская библиотека · Korean journal of ophthalmology : KJO · 2018

Effects of Choroidal Thickness on Refractive Outcome Following Cataract Surgery in Primary Angle Closure.

Song Woo Keun, Sung Kyung Rim, Shin Joong Won, Kwon Junki

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To identify the preoperative biometric factors, including subfoveal choroidal thickness (CT), associated with refractive outcome after cataract surgery in eyes with primary angle closure (PAC).

METHODS

This study included 50 eyes of 50 PAC patients who underwent uneventful cataract surgery. Preoperatively, anterior segment parameters including anterior chamber depth (ACD) and lens vault were determined by anterior segment optical coherence tomography. Subfoveal CT was measured by spectral domain optical coherence tomography enhanced depth imaging before and at one month after surgery. Mean refractive error (MRE) was calculated as the difference in spherical equivalent between actual postoperative refraction determined one month postoperatively and that predicted using each of three IOL calculation formulas (SRK/II, SRK/T, and Haigis). Regression analyses were performed to investigate potential associations between MRE and putative factors.

RESULTS

Mean ACD was 1.9 ± 0.4 mm, and preoperative subfoveal CT was 250.8 ± 56.9 μm. The SRK/T (MRE, 0.199 ± 0.567 diopters [D]) and Haigis (MRE, 0.190 ± 0.727 D) formulas showed slight hyperopic shift, while the SRK/II formula demonstrated a myopic shift (MRE, -0.077 ± 0.623 D) compared with that expected after cataract surgery. Mean absolute refractive error was not significantly different between formulas. Higher preoperative lens vault and shallower ACD were associated with a hyperopic shift in all formulas, but not in a statistically significant manner. Thicker preoperative subfoveal choroid was associated with a myopic shift after cataract surgery in all formulas (SRK/II: β = -0.511, p < 0.001; SRK/T: β = -0.652, p < 0.001; Haigis: β = -0.671, p < 0.001). Greater postoperative reduction of subfoveal CT was associated with a myopic shift after cataract surgery in all formulas (SRK/II: β = -0.511, p < 0.001; SRK/T: β = -0.652, p < 0.001; Haigis: β = -0.671, p < 0.001).

CONCLUSIONS

Our results indicate that preoperative subfoveal CT and the difference between pre- and postoperative subfoveal CT are significant factors for predicting refractive error after cataract surgery in PAC patients. These findings should be considered when performing cataract surgery to optimize visual outcomes.

Для цитирования: Song Woo Keun, Sung Kyung Rim, Shin Joong Won, Kwon Junki. Effects of Choroidal Thickness on Refractive Outcome Following Cataract Surgery in Primary Angle Closure.. Korean journal of ophthalmology : KJO. 2018. DOI: 10.3341/kjo.2017.0129.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.