MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00347-017-0474-2

Медицинская библиотека · Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2018

[Predictability of residual astigmatism after implantation of posterior chamber toric lenses].

Mies D, Klink T, Eisenbarth W, Meyer L M

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The objective of the study was to examine the predictability of residual astigmatism after cataract surgery and implantation of the posterior chamber aspheric toric lens TECNIS® ZCT, Abott Medical Optic (Ettlingen, Deutschland).

MATERIAL AND

METHODS

The retrospective study included a total of 88 patient eyes undergoing a cataract operation with a toric lens implantation between March 2014 and October 2015. The inclusion criteria were a regular astigmatism of at least 0.75 dpt. Posterior chamber toric lenses (model Tecnis ZCT) were exclusively implanted. Post-surgery check-ups were performed after 1 day, 1 month and 2 months. Main study outcome was best-corrected visual acuity (BCVA), spherical and astigmatic aberration and the difference between expected and actual residual astigmatism after cataract surgery.

RESULTS

The median reduction of corneal astigmatism was from -2.50 dpt (±1.06 dpt) to -0.75 dpt (±0.51 dpt) (p ≤ 0.05). The median BCVA increased from 0.37 logMAR (±0.25 logMAR) before surgery to 0.09 logMAR (±0.10 logMAR) after surgery. The spherical equivalent was reduced from +3.50 dpt (±1.11 dpt) (presurgery) to -0.56 dpt (±0.51 dpt) (postsurgery) in hyperopic patients and from -2.44 dpt (±3.03 dpt) to -0.69 dpt (±0.81 dpt) in myopic patients. By using the power vector analysis no significant deviation from the expected target values was observed; however, the median discrepancy between the expected and actual residual astigmatism was -0.50 dpt despite a surgical orientation of the intraocular lens (IOL) within 5° of the desired axis. The IOL showed a median rotation of 3.00° (±4.46°).

CONCLUSION

Implantation of the aspheric toric intraocular lens Tecnis ZCT is a predictable, effective and reproducible tool in cataract surgery to account for regular corneal astigmatis; however, despite an optimal surgical orientation of the toric IOL, a small and rarely a large discrepancy might occur between expected and actual residual astigmatism.

Для цитирования: Mies D, Klink T, Eisenbarth W, Meyer L M. [Predictability of residual astigmatism after implantation of posterior chamber toric lenses].. Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 2018. DOI: 10.1007/s00347-017-0474-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.