MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icb.0000000000000563

Медицинская библиотека · Retinal cases & brief reports · 2019

CHANGES IN THE POSTERIOR VITREOUS AFTER CATARACT SURGERY ASSESSED BY SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY.

Otsuka Yuki, Ooto Sotaro, Yoshimura Nagahisa

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess changes in the posterior vitreous caused directly by phacoemulsification with implantation of an intraocular lens, using the enhanced vitreous swept-source optical coherence tomography system (Topcon, Tokyo, Japan).

METHODS

Consecutive patients with cataract without posterior vitreous detachment were enrolled. Swept-source optical coherence tomography examinations were performed 1 day before and several days after surgery, using enhanced vitreous visualization. We compared preoperative and postoperative posterior vitreous status and measured the distance between the internal limiting membrane and the posterior vitreous membrane at 26 locations at the posterior pole.

RESULTS

Images of 33 eyes (21 patients) could be analyzed. The perifoveal posterior vitreous detachment was not extended in any eyes, and the internal limiting membrane to posterior vitreous membrane distance before and after surgery did not differ at any location measured (P = 0.071-1.000). The posterior precortical vitreous pocket was dilated in three eyes. Age, gender, axial length, preoperative visual activity, nuclear sclerosis, duration of surgery, and duration between surgery and swept-source optical coherence tomography did not differ between the dilated vitreous pocket group (n = 3) and the unchanged group (n = 30).

CONCLUSION

The height of the posterior vitreous membrane remained unchanged after surgery, although the posterior precortical vitreous pocket was dilated in three patients. Cataract surgery procedures seem to have little influence on the posterior vitreous membrane.

Для цитирования: Otsuka Yuki, Ooto Sotaro, Yoshimura Nagahisa. CHANGES IN THE POSTERIOR VITREOUS AFTER CATARACT SURGERY ASSESSED BY SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY.. Retinal cases & brief reports. 2019. DOI: 10.1097/icb.0000000000000563.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.