MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1708-8208.2009.00186.x

Медицинская библиотека · Clinical implant dentistry and related research · 2011

Thin bioactive ceramic-coated alumina-blasted/acid-etched implant surface enhances biomechanical fixation of implants: an experimental study in dogs.

Granato Rodrigo, Marin Charles, Gil Jose N, Chuang Sung-Kiang, Dodson Thomas B, Suzuki Marcelo, Coelho Paulo G

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Thin bioceramic coatings have been regarded as potential substitutes for plasma-sprayed hydroxyapatite coatings.

PURPOSE: This study tested the hypothesis that a thin bioactive ceramic coating deposition on an alumina-blasted/acid-etched (AB/AE) surface would positively affect the biomechanical fixation and bone-to-implant contact (BIC) of plateau root form implants.

MATERIALS AND

METHODS

Implants of two different lengths (i.e., 4.5 × 11 mm long, n = 36) and 4.5 × 6 mm (short, n = 36) and two different surfaces, that is, control (AB/AE) and test (AB/AE + 300 - 500 nm bioactive ceramic coating), were placed in the proximal tibiae of six beagle dogs. The implants were retrieved for analyses 2 and 4 weeks after placement. The implants in bone specimens were subjected to torque loads until a 10% drop of the maximum torque was recorded. The specimens were evaluated under optical microscopy for bone morphology and percent BIC. Statistical analysis was performed by a generalized linear mixed effects analysis of variance model and statistical significance set at p < 0.05.

RESULTS

Significantly higher torque-to-interface fracture levels for test surface groups of both lengths when compared to control surfaces were observed. No significant difference in BIC was observed between test and control implants of equal length. Histomorphological analysis showed higher degrees of bone organization between the plateaus of test implant surfaces at both implantation times.

CONCLUSION

Because the presence of a thin bioactive ceramic coating on the surface did not affect BIC, but positively affected implant biomechanical fixation, the hypothesis was partially validated.

Для цитирования: Granato Rodrigo, Marin Charles, Gil Jose N, Chuang Sung-Kiang, Dodson Thomas B, Suzuki Marcelo, Coelho Paulo G. Thin bioactive ceramic-coated alumina-blasted/acid-etched implant surface enhances biomechanical fixation of implants: an experimental study in dogs.. Clinical implant dentistry and related research. 2011. DOI: 10.1111/j.1708-8208.2009.00186.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.