MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.pdpdt.2016.08.004

Медицинская библиотека · Photodiagnosis and photodynamic therapy · 2016

Diagnostic accuracy of optical coherence tomography in actinic keratosis and basal cell carcinoma.

Olsen J, Themstrup L, De Carvalho N, Mogensen M, Pellacani G, Jemec G B E

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Early diagnosis of non-melanoma skin cancer (NMSC) is potentially possible using optical coherence tomography (OCT) which provides non-invasive, real-time images of skin with micrometre resolution and an imaging depth of up to 2mm. OCT technology for skin imaging has undergone significant developments, improving image quality substantially. The diagnostic accuracy of any method is influenced by continuous technological development making it necessary to regularly re-evaluate methods.

OBJECTIVE

The objective of this study is to estimate the diagnostic accuracy of OCT in basal cell carcinomas (BCC) and actinic keratosis (AK) as well as differentiating these lesions from normal skin.

METHODS

A study set consisting of 142 OCT images meeting selection criterea for image quality and diagnosis of AK, BCC and normal skin was presented uniformly to two groups of blinded observers: 5 dermatologists experienced in OCT-image interpretation and 5 dermatologists with no experience in OCT. During the presentation of the study set the observers filled out a standardized questionnaire regarding the OCT diagnosis. Images were captured using a commercially available OCT machine (Vivosight ®, Michelson Diagnostics, UK).

RESULTS

Skilled OCT observers were able to diagnose BCC lesions with a sensitivity of 86% to 95% and a specificity of 81% to 98%. Skilled observers with at least one year of OCT-experience showed an overall higher diagnostic accuracy compared to inexperienced observers.

CONCLUSIONS

The study shows an improved diagnostic accuracy of OCT in differentiating AK and BCC from healthy skin using state-of-the-art technology compared to earlier OCT technology, especially concerning BCC diagnosis.

Для цитирования: Olsen J, Themstrup L, De Carvalho N, Mogensen M, Pellacani G, Jemec G B E. Diagnostic accuracy of optical coherence tomography in actinic keratosis and basal cell carcinoma.. Photodiagnosis and photodynamic therapy. 2016. DOI: 10.1016/j.pdpdt.2016.08.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.