MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10029-025-03454-0

Медицинская библиотека · Hernia : the journal of hernias and abdominal wall surgery · 2025

"Comparative safety and efficacy of robotic TAPP and IPOM techniques in ventral hernia repair: a systematic review and meta-analysis of Short-term Outcomes".

Abdelsamad Ahmed, Khalil Ibrahim, Mohamed Khaled Ashraf, Ahmed Said Serour Aya Sayed, Mohammed Mohammed Khaled, Mostafa Noureldin, Badie Youssef Osama, Wesh Zeyad M, Mohamedosman Ali Alaeldin Mohamedsami, Gebauer Florian

СтатьяМетаанализСистематический обзорСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Robotic-assisted ventral hernia repair has gained popularity for its enhanced precision and visualization. Two main approaches-r-IPOM and r-TAPP-differ in technique and risk profiles. r-IPOM/+ is technically simpler and preferred for larger defects, but may increase seroma and bowel-related complications. Conversely, r-TAPP employs extraperitoneal mesh positioning, potentially reducing postoperative complications. This meta-analysis aimed to compare perioperative outcomes between r-IPOM and r-TAPP, focusing on seroma, surgical site infection (SSI), and hernia defect closure. Secondary outcomes included recurrence, reoperation, operative time, and hospital stay.

METHODS

A systematic meta-analysis, including 11 studies and 1001 patients, was performed. Pooled event rates and mean differences were calculated using random-effects models. Subgroup analyses based on mesh type and meta-regression assessing the impact of defect closure on complication rates were conducted. Evidence certainty was evaluated using the GRADE approach.

RESULTS

Both approaches achieved high defect closure rates (r-IPOM+: 98%, r-TAPP: 99%; p = 0.9). Seroma and hematoma rates were low without significant differences; however, r-IPOM showed a slightly higher trend. r-TAPP demonstrated a significantly lower Surgical site infection (SSI) rate (1%) compared to (r-IPOM 4%, p = 0.02), although these complications themselves did not differ significantly between groups, indicating a possible but unconfirmed association. Recurrence, reoperation, operative time, and hospital stay were comparable. Meta-regression indicated a non-significant trend toward fewer complications with higher closure rates (p = 0.09). The GRADE assessment rated the certainty of evidence as high across all outcomes.

CONCLUSION

Both r-TAPP and r-IPOM are effective and safe for robotic ventral hernia repair. A significant inverse correlation between closure rates and complication rates underscores the importance of complete, tension-free closure. While perioperative outcomes are largely comparable, r-TAPP may reduce infection risk likely due to lower seroma and hematoma rates. Approach selection should be guided by patient factors, anatomical considerations, and surgical expertise.

Для цитирования: Abdelsamad Ahmed, Khalil Ibrahim, Mohamed Khaled Ashraf, Ahmed Said Serour Aya Sayed, Mohammed Mohammed Khaled, Mostafa Noureldin, Badie Youssef Osama, Wesh Zeyad M, Mohamedosman Ali Alaeldin Mohamedsami, Gebauer Florian. "Comparative safety and efficacy of robotic TAPP and IPOM techniques in ventral hernia repair: a systematic review and meta-analysis of Short-term Outcomes".. Hernia : the journal of hernias and abdominal wall surgery. 2025. DOI: 10.1007/s10029-025-03454-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.