DOI 10.3390/diagnostics13081376

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2023

Validation of an Automated Cardiothoracic Ratio Calculation for Hemodialysis Patients.

Chou Hsin-Hsu, Lin Jin-Yi, Shen Guan-Ting, Huang Chih-Yuan

СтатьяПеревод пока не подготовлен

Аннотация

UNLABELLED: Cardiomegaly is associated with poor clinical outcomes and is assessed by routine monitoring of the cardiothoracic ratio (CTR) from chest X-rays (CXRs). Judgment of the margins of the heart and lungs is subjective and may vary between different operators.

METHODS

Patients aged > 19 years in our hemodialysis unit from March 2021 to October 2021 were enrolled. The borders of the lungs and heart on CXRs were labeled by two nephrologists as the ground truth (nephrologist-defined mask). We implemented AlbuNet-34, a U-Net variant, to predict the heart and lung margins from CXR images and to automatically calculate the CTRs.

RESULTS

The coefficient of determination (R2) obtained using the neural network model was 0.96, compared with an R2 of 0.90 obtained by nurse practitioners. The mean difference between the CTRs calculated by the nurse practitioners and senior nephrologists was 1.52 ± 1.46%, and that between the neural network model and the nephrologists was 0.83 ± 0.87% (p < 0.001). The mean CTR calculation duration was 85 s using the manual method and less than 2 s using the automated method (p < 0.001).

CONCLUSIONS

Our study confirmed the validity of automated CTR calculations. By achieving high accuracy and saving time, our model can be implemented in clinical practice.

Для цитирования: Chou Hsin-Hsu, Lin Jin-Yi, Shen Guan-Ting, Huang Chih-Yuan. Validation of an Automated Cardiothoracic Ratio Calculation for Hemodialysis Patients.. Diagnostics (Basel, Switzerland). 2023. DOI: 10.3390/diagnostics13081376.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.