MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1078-5884(97)80010-x

Медицинская библиотека · European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 1997

Mesothelial versus endothelial cell seeding: evaluation of cell adherence to a fibroblastic matrix using 111In oxine.

Bellón J M, García-Honduvilla N, Escudero C, Gimeno M J, Contreras L, de Haro J, Buján J

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to compare the behaviour of mesothelial cells (MC) to that of endothelial cells (EC) when seeded onto a PTFE, prosthesis coated with a fibroblastic matrix.

DESIGN, MATERIAL AND

METHODS

Three study groups were examined: a control group (Control) of PTFE prostheses with a fibroblast matrix (n = 8); Group EC, PTFE prostheses seeded with EC on a fibroblastic matrix (n = 8); and Group MC, PTFE, prostheses seeded with MC on a fibroblastic matrix (n = 8). All cell types were labelled with 111In (100 microCi/ml) 24 h after seeding, when the cells had formed a monolayer on the prosthetic surface. Radioactive levels were measured at 2, 4, 6, and 24 h.

RESULTS

Both EC and MC showed optimal adherence. The MC had a better radioactive uptake and retention than the EC. The number of EC and MC cells that remained adherent to the matrix was large enough to ensure complete covering of the prosthetic surface.

CONCLUSION

The use of MC is therefore feasible as an optimal alternative for achieving a natural covering on vascular prostheses prepared with a fibroblastic matrix.

Для цитирования: Bellón J M, García-Honduvilla N, Escudero C, Gimeno M J, Contreras L, de Haro J, Buján J. Mesothelial versus endothelial cell seeding: evaluation of cell adherence to a fibroblastic matrix using 111In oxine.. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery. 1997. DOI: 10.1016/s1078-5884(97)80010-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.