MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archopht.1995.01100050113040

Медицинская библиотека · Archives of ophthalmology (Chicago, Ill. : 1960) · 1995

The barrier function in neodymium-YAG laser capsulotomy.

Smith R T, Moscoso W E, Trokel S, Auran J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Complications following neodymium (Nd)-YAG laser capsulotomy have been attributed to damage to the capsule and vitreous face.

OBJECTIVES

To measure the disruption of the anterior-posterior extracapsular barrier complex induced by Nd-YAG laser capsulotomy and to determine how it might be minimized, using a fluorophotometer.

DESIGN

Prospective study of 21 eyes undergoing Nd-YAG laser capsulotomy and cross-sectional comparison with 15 pseudophakic eyes with clear capsules.

SETTING

University-based clinical practice.

INTERVENTION: Neodymium-YAG laser posterior capsulotomy per study protocol.

MAIN OUTCOME MEASURE: Change in extracapsular barrier efficiency as measured by fluorophotometry.

RESULTS

Multivariate regression demonstrated that both anterior vitreous disruption and absence of a posterior chamber intraocular lens (aphakia) were significantly correlated with loss of barrier efficiency, whereas capsulotomy size was not. The anterior vitreous was judged to be undamaged in 67% of eyes treated by the study protocol. However, all myopic eyes sustained damage. Opacification of the posterior capsule itself was also associated with mild loss of barrier function even before capsulotomy, compared with the clear-capsule group. Glaucoma occurred more frequently when barrier efficiency was lost postoperatively.

CONCLUSION

Damage to the extracapsular barrier complex by Nd-YAG laser capsulotomy is minimized when the anterior vitreous is preserved. The study treatment protocol may be useful in limiting this damage and in reducing complications.

Для цитирования: Smith R T, Moscoso W E, Trokel S, Auran J. The barrier function in neodymium-YAG laser capsulotomy.. Archives of ophthalmology (Chicago, Ill. : 1960). 1995. DOI: 10.1001/archopht.1995.01100050113040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.