MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0022-510x(88)90049-4

Медицинская библиотека · Journal of the neurological sciences · 1988

Lambert-Eaton myasthenic syndrome: the lack of short-term in vitro effects of serum factors on neuromuscular transmission.

Kim Y I, Sanders D B, Johns T R, Phillips L H, Smith R E

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

Serum was obtained from 7 patients with the Lambert-Eaton myasthenic syndrome (LES), 3 patients with small-cell carcinoma of the lung (SCCL), and 9 healthy control subjects. Serum samples were applied in vitro to the rat neuromuscular junction (for 1-3 h for control LES sera; 4 h for SCCL sera), following which the pre- and postjunctional physiological effects of serum factors were studied in the presence of 10 mM [Mg2+]o. All sera produced a marked reduction in the frequency of spontaneous miniature end-plate potentials (MEPPs), while causing slight to moderate changes in MEPP amplitude. There were no consistent changes in the quantum content of the impulse-evoked end-plate potentials, though the serum from one LES patient significantly and reversibly inhibited the evoked quantal release. No significant effect was found when a human intercostal muscle was exposed to serum from another LES patient for 2 h. Therefore, when applied in vitro on a short-term basis, the putative LES autoantibodies do not consistently react with voltage-dependent calcium channels in the motor nerve terminal and thus fail to reproduce the physiologic abnormality of the syndrome. We suggest that the pathogenic IgG molecules may require more than 3h of incubation in order to gain access to, and inhibit the function of, the prejunctional Ca2+ channels.

Для цитирования: Kim Y I, Sanders D B, Johns T R, Phillips L H, Smith R E. Lambert-Eaton myasthenic syndrome: the lack of short-term in vitro effects of serum factors on neuromuscular transmission.. Journal of the neurological sciences. 1988. DOI: 10.1016/0022-510x(88)90049-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.