MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/ice.2025.10347

Медицинская библиотека · Infection control and hospital epidemiology · 2025

Long-range air dispersal as an important source of environmental contamination in Candida auris clustering: possible infection control implication.

Fung Wing-Yu, Cheng Ryan Yiu-Fai, Yau Anthony Pak-Yuen, Lee Suet-Yi, Chan Nga-Han, Wong Yuk-Shan, Choi Garnet Kwan-Yue, Tse Herman, Wong Sally Cheuk-Ying, Lung David Christopher

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To analyze the correlation between scale of Candida auris clustering and extent of environmental contamination, exploring its implications for improving infection control measures in healthcare settings.

DESIGN

Retrospective observational study.

SETTING

An acute hospital and a convalescent hospital in Hong Kong.

PATIENTS: Laboratory confirmed C. auris carriers diagnosed in two hospitals between March and October 2023.

METHODS

C. auris screening was conducted on patients with defined risk factors and through regular surveillance. Environmental samples were collected from high-touch surfaces and air grilles in corresponding wards.

RESULTS

One-hundred-seventy new C. auris patients were identified, including 65 from nine outbreaks and 105 sporadic cases. Environmental screening from eight outbreaks and 46 sporadic isolated cases was analyzed. The environmental contamination rate was significantly higher in the outbreak group (15.1% vs 2.6%, P < 0.05). Longer outbreak duration (34 vs 7 days, P < 0.05) and a higher median number of affected patients per outbreak (9 vs 5, P = 0.05) were associated with higher contamination rates. Notably, air grille samples had a significantly higher contamination rate than high-touch surfaces in both the outbreak (31.6% vs 10.2%, P < 0.05) and sporadic groups (4.6% vs 1.5%, P < 0.05).

CONCLUSION

Prolonged and sizeable C. auris clusterings were linked with more extensive environmental contamination, particularly in air grilles, which are often overlooked during decontaminationThese findings underscore the need for enhanced infection control measures, including thorough environmental decontamination of air ventilation systems, to mitigate transmission risks in healthcare settings.

Для цитирования: Fung Wing-Yu, Cheng Ryan Yiu-Fai, Yau Anthony Pak-Yuen, Lee Suet-Yi, Chan Nga-Han, Wong Yuk-Shan, Choi Garnet Kwan-Yue, Tse Herman, Wong Sally Cheuk-Ying, Lung David Christopher. Long-range air dispersal as an important source of environmental contamination in Candida auris clustering: possible infection control implication.. Infection control and hospital epidemiology. 2025. DOI: 10.1017/ice.2025.10347.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.