m+Medelevator.RU
← Поиск публикаций
International heart journal · 2023

Optimal Timing of Serial 18F-Fluoro-2-Deoxyglucose Positron Emission Tomography after Prednisolone Treatment Introduction for Cardiac Sarcoidosis.

Наблюдательное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ishizuka Mitsuo, Kashimura Takeshi, Watanabe Mitsuhiro, Kase Mayumi, Sakai Ryohei, Okubo Takeshi, Fujiki Shinya, Takayama Tsugumi, Ishihara Shiro, Ozaki Kazuyuki, Inomata Takayuki

Аннотация

Immunosuppressive therapy with prednisolone (PSL) is the first-line treatment for cardiac sarcoidosis (CS), and 18F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET) is used to evaluate its efficacy to guide treatment. However, the appropriate timing of FDG-PET in CS remains unknown. This single-center, retrospective, observational study included 15 consecutive CS patients who underwent 3 serial FDG-PET scans (at baseline, in the early phase [1-2 months after PSL introduction], and in the late phase [≥ 5 months after PSL introduction with a maintenance dose of PSL]). We adhered to the PSL tapering protocol by the Japanese Circulation Society even when early FDG-PET showed positive results (SUVmax ≥ 4.0). No patient died during the 908 (644-1600) days of observation. Negative results in the late phase were observed in 3 of 6 early-positive patients, and 3 of 9 early-negative patients showed positive results in the late phase. Changes in echocardiographic parameters from baseline to the late phase were significantly better in late-negative patients than in late-positive patients (left ventricular end-diastolic diameter: -0.7 (-9.3-[-0.5]) mm versus +3.5 (0.8-7.5) mm, P = 0.039; left ventricular end-systolic diameter: -4.2 (-6.9-[-0.1]) mm versus +5.1 (0.5-7.0) mm, P = 0.015; left ventricular ejection fraction: +4.7% (-1.0-9.0%) versus -1.5% (-11.3-1.5%), P = 0.045) ), although early FDG-PET did not predict those consequent changes. An interval of ≥ 5 months after introducing the PSL with a maintenance dose of PSL is long enough for FDG-PET to reflect consequent left ventricular functions, while an interval of 1-2 months can be too short.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты