MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2023.117678

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2023

Development and validation of equilibrium dialysis UHPLC-MS/MS measurement procedures for total and unbound concentrations of bictegravir, dolutegravir, darunavir and doravirine in human plasma. Application to patients with HIV.

Rigo-Bonnin Raúl, García-Tejada Laura, Mas-Bosch Virgínia, Imaz Arkaitz, Manuel Tiraboschi Juan, Scévola Sofía, Niubó Jordi, Navarro-Alcaraz Antonio, Podzamczer Daniel

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Fixed-dose combinations of antiretroviral drugs are commonly used to treat HIV infection and therapeutic monitoring is not part of routine clinical practice. However, drug concentrations monitoring might have role in different clinical scenarios as well as for research purposes. This study aimed to develop and validate UHPLC-MS/MS procedures for measuring total and unbound concentrations of bictegravir, dolutegravir, darunavir and doravirine in human plasma.

MATERIAL AND

METHODS

Equilibrium dialysis preceded sample preparation (based on protein precipitation) for measuring unbound antiretroviral concentrations. Chromatographic separations were achieved on an Acquity®-UPLC® HSS™-T3 column (50 mm × 2.1 mm; 1.8 µm) using a non-linear water/acetonitrile gradient containing 0.1 % formic acid at a 0.5 mL/min flow rate. Antiretrovirals were detected by tandem mass spectrometry in positive electrospray ionisation and multiple reaction monitoring modes.

RESULTS

No significant interferences or carry-over were observed. Imprecisions, absolute relative biases, normalised matrix effects and recoveries were ≤15.0 %, ≤11.1 %, (94.7-104.1)% and (96.7-105.5)%, respectively. Non-linear measuring intervals were observed between (25-10,000) µg/L for total/plasma dialysate concentrations and linearity schemes (1.00-100) µg/L for buffer dialysate concentrations.

CONCLUSIONS

The UHPLC-MS/MS procedures developed could be used for research purposes and therapeutic drug monitoring of antiretrovirals in routine clinical practice.

Для цитирования: Rigo-Bonnin Raúl, García-Tejada Laura, Mas-Bosch Virgínia, Imaz Arkaitz, Manuel Tiraboschi Juan, Scévola Sofía, Niubó Jordi, Navarro-Alcaraz Antonio, Podzamczer Daniel. Development and validation of equilibrium dialysis UHPLC-MS/MS measurement procedures for total and unbound concentrations of bictegravir, dolutegravir, darunavir and doravirine in human plasma. Application to patients with HIV.. Clinica chimica acta; international journal of clinical chemistry. 2023. DOI: 10.1016/j.cca.2023.117678.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.